HKR Installation Manual

6
Figure 8
Figure 9
NOTE: In some cases, it will be easier to wire the
breakers BEFORE inserting them into the electric heat
kit box. If rewiring is desired, reference the included
wiring diagram to ensure correct wiring.
15. Insert the power leads into the lugs provided on the
circuit breaker or terminal block and tighten. Ensure
the power leads are routed through the outer cabinet
with a watertight electrical connector, sized
appropriately for the electrical power supply (see
NEC, National Electric Code).
CIRCUIT BREAKER
MOUNTING PLATE
Figure 10
16. Remove the protection plug (male plug) and discard.
Insert the one provided in the electric heat kit. It
can be inserted in one position only.
17. Insert the ground wire into the lug(s) provided for
that purpose.
18. Break out the appropriate area of the electric heat
kit cover previously removed for the circuit breaker
provided in the heater kit and replace electric heat
kit cover.
NOTE: To replace the electric heat kit cover, slightly
tip the cover and insert only the notches under the
flanges on the top and bottom of the box. Secure
with screws. See Figure 11.
ATTACH CIRCUIT BREAKER
MOUNTING BRACKET
WITH PROVIDED
SHEET METAL SCREW
TIP IN SLIGHTLY
AND SECURE
NOTCHES
BEHIND FLANGE
FLANGE
CIRCUIT
BREAKER
KNOCKOUTS
SCREW
ATTACH CIRCUIT BREAKER
MOUNTING BRACKET
WITH PROVIDED
SHEET METAL SCREW
Figure 11