ElEctRicAl dAtA foR gPc15m PAcKAgEd UnitS (BloWER only, HEAt modE)
See Notes on the following page.
Model and
Heat Kit Usage
Circuit #1 Circuit #2
Actual kW /
BTU@ 240V
MCA¹ MOP² MCA¹ MOP²
GPC1524M41 2.4 --- --- --- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 ---- ---- 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 ---- ---- 7.00 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 ---- ---- 9.50 / 32,400
GPC1530M41 2.4 --- --- --- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 7.0 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 9.5 / 32,400
HKP-15C* 43 / 49 45 / 50 21 / 25 25 / 25 14.25 / 48,600
GPC1536M41 2.4 --- --- --- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 7.00 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 9.50 / 32,400
HKP-15C* 43 / 49 45 / 50 21 / 25 25 / 25 14.25 / 48,600
GPC1542M41 3.6 --- --- --- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 7.0 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 9.5 / 32,400
HKP-15C* 43 / 49 45 / 50 21 / 25 25 / 25 14.25 / 48,600
GPC1548M41 3.6 --- --- --- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 7.00 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 9.50 / 32,400
HKP-15C* 43 / 49 45 / 50 21 / 25 25 / 25 14.25 / 48,600
HKP-20C* 43 / 49 45 / 50 43 / 49 45 / 50 19.0 / 64,800
¹ Minimum Circuit Ampacity @ 208 / 240 V
² Maximum Overcurrent Protecon Device @ 208 / 240 V
* Revision level that may or may not be designated
C Circuit breaker opon
^ Heat Kit requires three-phase power supply
Note: HKP-15C* and HKP-20C* replace HKR-15C and HKR-20C respecvely to meet new UL1995 requirements.