ElEctRicAl dAtA foR gPc13H PAcKAgEd UnitS (BloWER only, HEAt modE)
Model and
Heat Kit Usage
Circuit #1 Circuit #2 Single-Point Kit
Actual kW /
BTU@ 240V
MCA¹ MOP² MCA¹ MOP² MCA¹ MOP²
GPC1324H41** 1.9 --- --- --- -- -- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 24 / 27 25 / 30 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 33 / 38 35 / 40 7 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 45 / 51 50 / 60 9.5 / 32,400
GPC1330H41** 2.3 --- --- --- -- -- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 24 / 27 30 / 30 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 34 / 39 40 / 40 7 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 45 / 52 60 / 60 9.5 / 32,400
HKP-15C* 43 / 49 45 / 50 21 / 25 25 / 25 67 / 77 70 / 80 14.25 / 48,600
GPC1336H41** 2.3 --- --- --- -- -- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 24 / 27 40 / 40 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 34 / 39 40 / 40 7 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 45 / 52 60 / 60 9.5 / 32,400
HKP-15C* 43 / 49 45 / 50 21 / 25 25 / 25 67 / 77 70 / 80 14.25 / 48,600
GPC1342H41** 3.6 --- --- --- -- -- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 27 40 / 40 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 34 / 39 40 / 40 7 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 46 / 52 60 / 60 9.5 / 32,400
HKP-15C* 43 / 49 45 / 50 21 / 25 25 / 25 68 / 78 70 / 80 14.25 / 48,600
HKP-20C 43 / 49 45 / 50 43 / 49 45 / 50 90 / 103 90 / 110 19.0 / 64,800
GPC1349H41** 3.6 --- --- --- -- -- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 29 45 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 34 / 40 45 7 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 46 / 53 60 / 60 9.5 / 32,400
HKP-15C 43 / 49 45 / 50 21 / 25 25 / 25 68 / 78 70 / 80 14.25 / 48,600
HKP-20C 43 / 49 45 / 50 43 / 49 45 / 50 90 / 103 90 / 110 19.0 / 64,800
GPC1360H41** 7.5 --- --- --- -- -- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 40 60 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 40 60 7 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 48 / 54 60 / 60 9.5 / 32,400
HKP-15C 43 / 49 45 / 50 21 / 25 25 / 25 70 / 80 80 / 90 14.25 / 48,600
HKP-20C 43 / 49 45 / 50 43 / 49 45 / 50 92 / 105 100 / 110 19.0 / 64,800
¹ Minimum Circuit Ampacity @ 208 / 240 V
² Maximum Overcurrent Protecon Device @ 208 / 240 V
* Revision level that may or may not be designated
C Circuit breaker opon
^ Heat Kit requires three-phase power supply
Note: HKP-15C* and HKP-20C* replace HKR-15C and HKR-20C respecvely to meet new UL1995 requirements.