HKS Spec Sheet
32 www.goodmanmfg.com SS-GHKR
SS-GHKR www.goodmanmfg.com 33
Air Handler Electrical Data — MBVC
MBVC1200AA-1A*
HKR-03*
HKR-05* / 05C*
HKR-06*
HKR-08* / -08C*
HKR-10* / -10C*
HKA-15C*
0 / 0
10.8 / 12.5
17.2 / 19.8
21.7 / 25.0
25.3 / 29.2
34.3 / 39.6
34.3 / 39.6
4.9 / 4.9
18 / 20.5
26 / 29.6
32 / 36.1
36.5 / 41
47.8 / 54
47.8 / 54
15 / 15
20 / 25
30 / 30
35 / 40
40 / 45
50 / 60
50 / 60
---
---
---
---
---
---
17.2 / 19.8
---
---
---
---
---
---
21.4 / 24.7
---
---
---
---
---
---
25 / 25
---
---
---
---
---
---
69/79
---
---
---
---
---
---
70 / 80
MBVC1600AA-1A*
HKR-03*
HKR-05* / 05C*
HKR-06*
HKR-08* / -08C*
HKR-10* / -10C*
HKA-15C*
0 / 0
10.8 / 12.5
17.2 / 19.8
21.7 / 25.0
25.3 / 29.2
34.3 / 39.6
34.3 / 39.6
6.5 / 6.5
20.1 / 22
27.9 / 31
34 / 37.8
38.1 / 43
49.4 / 56
49.4 / 56
15 / 15
25 / 25
30 / 35
35 / 40
40 / 45
50 / 60
50 / 60
---
---
---
---
---
---
17.2 / 19.8
---
---
---
---
---
---
21.4 / 24.7
---
---
---
---
---
---
25 / 25
---
---
---
---
---
---
71/81
---
---
---
---
---
---
80 / 90
MBVC2000AA-1A*
HKR-03*
HKR-05* / 05C*
HKR-06*
HKR-08* / -08C*
HKR-10* / -10C*
HKA-15C*
HKA-20C*
0 / 0
10.8 / 12.5
17.2 / 19.8
21.7 / 25.0
25.3 / 29.2
34.3 / 39.6
34.3 / 39.6
34.3 / 39.6
6.5 / 6.5
20.1 / 22
27.9 / 31
34 / 37.8
38.1 / 43
49.4 / 56
49.4 / 56
49.4 / 56
15 / 15
25 / 25
30 / 35
35 / 40
40 / 45
50 / 60
50 / 60
50 / 60
---
---
---
---
---
---
17.2 / 19.8
34.3 / 39.6
---
---
---
---
---
---
21.4 / 24.7
42.9 / 49.5
---
---
---
---
---
---
25 / 25
45 / 50
---
---
---
---
---
---
70/80
92/105
---
---
---
---
---
---
70 / 80
100 / 110
All ampacies noted above include air handler motor amps
Circuit 1: Single-phase for Air Handlers / Circuit 2: Three-phase for HKR3 Heater
Kits
¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25
² Maximum Overcurrent Protecon = 2.25 X Motor Amps + Heater Amps
* Revision level that may or may not be designated
C = Circuit Breaker Opon
--- indicates Not Required
• Only applicable when HKA kits are included in table
HKA meets the new UL1995 requirements for 15 and 20KW heaters
• MBVC and MBR models
Heating kW Correction Factor
240 230 220 210 208
1.00 0.92 0.84 0.77 0.75
Mulply the 240-volt heang capacity by correcon factors.