TECHNICAL MANU AL MANUAL GPH 13 H SERIES HORIZONTAL Package Heat Pump Units with R-410A • Refer to Service Manual RS6300011 (Horizontal) for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3 This manual is to be used by qualified, professionally trained HVAC technicians only.
PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GPH1324H41AB GPH1330H41AB GPH1336H41AC GPH1342H41AB GPH1348H41BB GPH1360H41BB WARNING The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit.
PRODUCT DESIGN GPH Package Units are designed for outdoor installations only in either residential or light commercial applications. The connecting ductwork (Supply and Return) can only be connected for horizontal airflow. A return air filter must be installed behind the return air grille(s) or provision must be made for a filter in an accessible location within the return air duct. The minimum filter area should not be less than those sizes listed in the Specification Section.
PRODUCT DESIGN 36" WARNING UN IT PL EN UM 24" PL AT FO RM RB CU 36" TO PREVENT POSSIBLE PROPERTY DAMAGE, THE UNIT SHOULD REMAIN IN AN UPRIGHT POSITION DURING ALL RIGGING AND MOVING OPERATIONS. TO FACILITATE LIFTING AND MOVING IF A CRANE IS USED, PLACE THE UNIT IN AN ADEQUATE CABLE SLING. Refer to Roof curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual.
PRODUCT DESIGN GPH1324-1360H41** ELECTRICAL DATA (*Blower Only, Heat Mode) Circuit #1 Model and Heat Kit Usage GPH1324H41** HKR05*,C* HKR08*,C* HKR10*,C* GPH1330H41** HKR05*,C* HKR08*,C* HKR10*,C* HKR15*,C* Circuit #2 Minimum Circuit Ampacity at 208 / 240V Maximum Overcurrent Protection (amps) at 208 / 240V Minimum Circuit Ampacity at 208 / 240V Maximum Overcurrent Protection (amps) at 208 / 240V Actual kW & BTU at 240V 24 / 27 33 / 28 45 / 51 30 / 30 40 / 40 60 / 60 ---------- ---------- 4.
PRODUCT DIMENSIONS GPH13[24-60]H41** A 14.000 4.512 4.500 14.000 SUPPLY 14.000 RETURN 6.500 BACK VIEW (DUCT OPENINGS) 66.542 B 34.075 Chassis Small Medium Large Model A B GPH1324H41** 22.000 29.932 GPH1330H41** 22.000 29.932 GPH1336H41** 24.000 34.932 GPH1342H41** 24.000 34.932 GPH1348H41** 24.000 38.682 GPH1360H41** 24.000 38.
GPH13[24-36]H41AB GPH1336H41AC PACKAGE HEAT PUMP SPECIFICATIONS GPH1324H41** GPH1330H41** GPH1336H41** 24,000 28,200 35,000 13.00 13.00 13.00 22,000 27,000 33,600 35°/33°F 17,600 20,400 27,000 17°/15°F 14,000 15,000 18,000 COOLING COOLING CAPACITY, BTUH CAPACITY SEER 47°/43°F HEATING RATING HSPF 7.7 7.7 7.7 208/230-60-1 208/230-60-1 208/230-60-1 AMPS 15.4 17.06 20.06 MIN CIRCUIT AMPACITY 18.6 20.6 24.2 30 30 40 SCROLL SCROLL SCROLL RATED LOAD AMPS 12.8 14.
PACKAGE HEAT PUMP SPECIFICATIONS GPH1342H41AB GPH13[48-60]H41BB GPH1342H41** GPH1348H41** GPH1360H41** COOLING COOLING CAPACITY, BTUH 40,500 46,000 57,500 CAPACITY SEER 47°/43°F 13.00 13.00 13.00 HEATING RATING 38,000 44,500 54,400 35°/33°F 30,000 33,000 39,000 17°/15°F 21,800 26,000 32,000 7.8 7.7 7.7 208/230-60-1 208/230-60-1 208/230-60-1 HSPF UNIT VOLTAGE (NAMEPLATE) ELECTRICAL AMPS 22.2 24.17 33.6 SPECIFICATION MIN CIRCUIT AMPACITY 26.6 29.2 40.
ACCESSORIES Part Number Description OT18-60A Outdoor Thermostat Kit w/Lockout Stat OT/EHR18-60 Emergency Heat Relay Kit HKR Electric Heat Kit PCCP101-103 Roof Curb PCP101-103 Downflow Plenum Kit PCP101-103R8 Downflow Plenum Kit w/ R-8 Insulation GPCED101-103 Downflow Economizer for GPC-(H) A/C - To Be Used With PCP101-103 GPHED101-103 Downflow Economizer for GPH-(H) Heat Pump - To Be Used With PCP101-103 GPCEH101-103 Horizontal Economizer for GPC-(H) A/C GPHEH101-103 Horizontal Economiz
GPH13[24-60]H41** BLOWER PERFORMANCE DATA Speed LOW 230 MED 230 HIGH 230 LOW 230 GPH1360H41** GPH1348H41** GPH1342H41** GPH1336H41** GPH1330H41** Model GPH1324H41** Dry Coil Data Volts CFM WATTS CFM WATTS CFM WATTS CFM E.S.P (In. of H2 O) 0.1 680 0.2 640 0.3 590 0.4 555 0.5 505 0.6 440 0.7 340 0.
10 20 30 40 50 60 70 30 80 90 100 40 50 60 700 600 CFM 90 100 2000 2200 2400 CFM 1800 1600 1400 OUTPUT BTU/HR x 1000 80 1200 1100 1000 900 70 800 FORMULAS 110 120 130 140 BTU OUTPUT = CFM x 1.08 x RISE BTU OUTPUT RISE = ÷ CFM 1.
EXPANDED PERFORMANCE DATA 23.7 0.64 16 1.73 7.3 257 118 22.5 0.61 16 1.70 7.2 252 116 24.6 0.81 19 1.76 7.5 263 120 23.9 0.78 20 1.74 7.4 260 119 22.7 0.74 20 1.72 7.3 255 117 MBh 22.8 S/T 0.76 Delta T 18 KW 1.69 AMPS 7.2 HI PR 239 LO PR 111 MBh 21.7 S/T 0.73 Delta T 19 KW 1.67 AMPS 7.1 HI PR 234 LO PR 109 MBh 23.9 S/T 0.91 Delta T 20 KW 1.72 AMPS 7.3 HI PR 244 LO PR 113 MBh 23.2 S/T 0.87 Delta T 21 KW 1.71 AMPS 7.2 HI PR 242 LO PR 112 MBh 22.1 S/T 0.83 Delta T 22 KW 1.68 AMPS 7.
EXPANDED PERFORMANCE DATA 24.8 1.00 23 1.75 7.4 249 115 24.0 1.00 25 1.73 7.4 246 114 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 770 980 875 22.5 0.91 24 1.69 7.2 239 111 MBh S/T Delta T KW AMPS HI PR LO PR 875 24.5 0.96 25 1.77 7.5 265 122 25.2 1.00 24 1.78 7.6 268 123 22.9 0.86 23 1.73 7.3 257 118 24.1 0.89 23 1.76 7.5 263 120 25.7 0.87 23 1.82 7.7 280 133 26.4 0.91 23 1.84 7.8 283 134 24.5 0.70 20 1.78 7.5 272 129 25.8 0.73 20 1.81 7.7 277 131 27.4 0.
EXPANDED PERFORMANCE DATA 28.9 0.81 18 2.09 8.9 268 120 28.1 0.77 19 2.07 8.8 265 119 MBh 28.1 S/T 0.91 Delta T 20 KW 2.04 AMPS 8.7 HI PR 249 LO PR 113 MBh 27.3 S/T 0.86 Delta T 21 KW 2.03 AMPS 8.7 HI PR 247 LO PR 112 920 1180 1050 25.7 0.61 16 2.01 8.6 255 114 MBh 24.8 S/T 0.73 Delta T 18 KW 1.97 AMPS 8.4 HI PR 237 LO PR 107 1050 30.4 0.58 16 2.13 9.1 280 130 31.3 0.61 15 2.15 9.1 283 131 28.1 0.42 12 2.07 8.8 269 125 30.5 0.44 12 2.12 9.0 277 129 32.6 0.38 11 2.20 9.4 292 138 33.6 0.
EXPANDED PERFORMANCE DATA 29.7 1.00 23 2.12 9.0 273 123 28.8 0.96 24 2.10 9.0 271 121 MBh 29.1 S/T 1.00 Delta T 23 KW 2.08 AMPS 8.9 HI PR 254 LO PR 115 MBh 28.3 S/T 0.99 Delta T 25 KW 2.06 AMPS 8.8 HI PR 252 LO PR 114 920 1180 1050 26.2 0.86 22 2.04 8.7 260 117 MBh 25.6 S/T 0.91 Delta T 23 KW 2.00 AMPS 8.5 HI PR 242 LO PR 110 1050 30.2 0.86 23 2.17 9.2 286 132 31.1 0.91 22 2.18 9.3 289 134 28.0 0.70 19 2.10 8.9 275 127 30.3 0.72 19 2.15 9.2 283 131 32.2 0.70 20 2.23 9.5 298 141 33.1 0.
EXPANDED PERFORMANCE DATA 34.9 0.86 20 2.63 11.2 250 111 33.9 0.82 21 2.61 11.1 247 110 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1050 1350 1200 30.7 0.70 19 2.53 10.8 237 106 MBh S/T Delta T KW AMPS HI PR LO PR 1200 34.9 0.73 20 2.66 11.3 266 117 35.9 0.77 19 2.68 11.4 269 118 31.9 0.58 16 2.58 11.0 255 113 34.5 0.60 16 2.64 11.2 263 116 37.7 0.56 16 2.74 11.6 281 128 38.9 0.58 15 2.76 11.7 284 129 34.9 0.40 12 2.66 11.3 270 123 37.8 0.42 12 2.72 11.
EXPANDED PERFORMANCE DATA 36.1 0.99 24 2.67 11.4 255 114 35.1 0.94 25 2.65 11.3 252 112 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1050 1350 1200 31.8 0.87 24 2.57 10.9 242 108 MBh S/T Delta T KW AMPS HI PR LO PR 1200 35.7 0.91 25 2.70 11.5 271 120 36.8 0.96 24 2.72 11.6 274 121 32.5 0.81 23 2.62 11.2 261 115 35.2 0.84 23 2.68 11.4 269 118 37.4 0.82 24 2.78 11.8 287 131 38.6 0.86 23 2.80 11.9 289 132 34.7 0.66 20 2.70 11.5 275 125 37.6 0.69 20 2.76 11.
EXPANDED PERFORMANCE DATA 40.4 0.86 20 2.85 12.5 238 114 39.2 0.82 21 2.82 12.4 235 113 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1236 1585 1410 35.6 0.70 18 2.74 12.0 226 109 MBh S/T Delta T KW AMPS HI PR LO PR 1410 40.3 0.74 19 2.88 12.6 253 120 41.6 0.77 19 2.90 12.7 256 122 36.9 0.58 16 2.80 12.3 243 116 39.9 0.61 16 2.86 12.5 251 119 43.7 0.56 16 2.96 13.0 267 132 45.0 0.58 15 2.98 13.1 270 133 40.4 0.40 12 2.88 12.6 257 126 43.8 0.42 12 2.94 12.
EXPANDED PERFORMANCE DATA 41.8 0.99 24 2.89 12.7 242 117 40.6 0.95 25 2.87 12.6 240 116 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1236 1585 1410 36.8 0.87 24 2.78 12.2 230 111 MBh S/T Delta T KW AMPS HI PR LO PR 1410 41.4 0.91 25 2.92 12.8 258 123 42.6 0.96 24 2.94 12.9 261 124 37.6 0.82 23 2.84 12.5 248 118 40.8 0.85 23 2.90 12.7 256 122 43.3 0.82 23 3.01 13.2 273 134 44.6 0.86 22 3.03 13.3 275 136 40.2 0.66 20 2.92 12.8 262 129 43.5 0.69 20 2.98 13.
EXPANDED PERFORMANCE DATA 45.8 0.88 21 3.12 13.7 230 110 44.5 0.84 22 3.09 13.6 228 109 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1400 1800 1600 40.4 0.72 19 3.01 13.2 219 105 MBh S/T Delta T KW AMPS HI PR LO PR 1600 45.8 0.75 20 3.15 13.8 245 116 47.2 0.79 19 3.18 13.9 248 118 41.9 0.60 16 3.06 13.4 235 112 45.4 0.62 16 3.13 13.7 243 115 49.6 0.57 16 3.24 14.2 259 127 51.1 0.60 16 3.27 14.3 261 128 45.9 0.41 12 3.15 13.8 249 122 49.7 0.43 12 3.22 14.
EXPANDED PERFORMANCE DATA 47.5 1.00 24 3.16 13.9 235 113 46.1 0.97 26 3.14 13.8 232 112 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1400 1800 1600 41.8 0.89 25 3.05 13.4 223 107 MBh S/T Delta T KW AMPS HI PR LO PR 1600 47.0 0.94 25 3.20 14.0 250 119 48.4 0.98 24 3.22 14.2 253 120 42.7 0.84 23 3.11 13.6 240 114 46.3 0.87 23 3.18 13.9 248 118 49.2 0.84 24 3.29 14.4 264 130 50.7 0.89 23 3.31 14.5 267 131 45.6 0.68 20 3.19 14.0 254 124 49.5 0.71 20 3.27 14.
EXPANDED PERFORMANCE DATA 57.3 0.85 21 3.89 16.3 235 108 55.6 0.81 22 3.85 16.2 233 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1621 2079 1850 50.5 0.69 20 3.73 15.7 223 103 MBh S/T Delta T KW AMPS HI PR LO PR 1850 57.3 0.72 21 3.94 16.5 250 114 59.0 0.76 20 3.97 16.7 253 115 52.3 0.57 17 3.81 16.0 240 109 56.7 0.59 17 3.90 16.4 248 113 62.0 0.55 17 4.06 17.0 264 124 63.9 0.57 16 4.09 17.2 267 126 57.3 0.40 13 3.93 16.5 254 120 62.1 0.41 13 4.03 16.
EXPANDED PERFORMANCE DATA 85 1850 58.7 0.90 26 4.00 16.8 255 116 61.5 0.81 25 4.12 17.3 270 127 63.3 0.85 24 4.16 17.4 272 128 65.6 0.66 21 4.26 17.9 281 135 67.6 0.69 21 4.29 18.0 284 137 61.0 0.49 17 4.12 17.3 270 130 56.3 0.96 27 4.22 17.6 266 116 58.0 1.00 26 4.25 17.8 269 117 51.0 0.89 26 4.08 17.1 256 111 55.3 0.92 25 4.18 17.5 264 114 57.4 0.93 26 4.31 18.0 286 123 59.1 0.97 25 4.34 18.2 289 124 52.2 0.83 25 4.17 17.4 275 118 56.5 0.86 24 4.27 17.9 284 122 60.1 0.84 25 4.44 18.
PACKAGE HEAT PUMP SPECIFICATIONS GPH13[24-36]H41** EXPANDED PERFORMANCE DATA MODEL: GPH1324H41* Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 MBh 27.7 26.2 24.6 23.0 22.0 21.3 19.8 18.3 17.4 16.1 14.8 14.0 DELTA T 29.3 27.7 26.1 24.4 23.3 22.6 21.0 19.3 18.5 17.0 15.7 14.8 KW 2.01 1.97 1.94 1.90 1.88 1.86 1.82 1.78 1.82 1.78 1.74 1.72 AMPS 9.6 9.0 8.5 8.1 7.8 7.7 7.3 7.0 6.7 6.5 6.2 6.1 COP 4.02 3.88 3.73 3.55 3.43 3.36 3.18 3.00 2.81 2.65 2.50 2.39 EER 13.7 13.3 12.7 12.1 11.7 11.5 10.
PACKAGE HEAT PUMP SPECIFICATIONS GPH13[42-60]H41** EXPANDED PERFORMANCE DATA MODEL: GPH1348H41** HEATING OPERATION Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 MBh 55.9 53.0 49.8 46.6 44.5 43.1 40.1 36.9 32.4 29.9 27.5 26.0 DELTA T 32.4 30.6 28.8 27.0 25.8 25.0 23.2 21.4 18.7 17.3 15.9 15.0 KW 3.72 3.65 3.58 3.52 3.48 3.45 3.38 3.32 3.40 3.33 3.26 3.22 AMPS 19.1 17.9 16.9 16.1 15.6 15.4 14.6 14.0 13.5 13.1 12.6 12.3 COP 4.40 4.24 4.07 3.88 3.74 3.66 3.46 3.26 2.79 2.63 2.47 2.
GPH1324, 30, 42H41AB / GPH1336H41AC GPH1348H41BB WIRING DIAGRAMS LPS SEE NOTE #8 SEE NOTE #7 YL/PK BK RD 1 G YL BL EBTDR R XFMR-R YL C SPEED UP HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
WIRING DIAGRAMS GPH1360H41BB SEE NOTE 8 SEE NOTE 3 PU LPS SEE NOTE 7 BK PU PU YL/PK 1 2 3 C 208 240 YL/PK PU BL 24V YL BK BL RD BL C BL BL BK BK YL 2 0 8 2 4 0 / 1 / L2 T2 RD SEE NOTE 5 L1 T1 PU BK BL BK PU RD PU GR GND GR 60 Y C C Y C C-RV PU CCR YL BK O-RV LVDR RD RD O PS2 RD BR WH PU GR WH W LVJB R YL BL BL DF2 WH H C F YL RD GR WH OR BR BL PLF BK R HVDR GR 3 6 9 2 5 8 1 4 7 R-DFT DF1 DFT RD YL RCCF RD BR RD BR PU