User Manual
Table Of Contents
41
03 OTHERS
User Manual V1.3
Technical Data GW7600A-BP GW8600A-BP GW9600A-BP
Protection
Back-up Output Short Protection Integrated
Output Over Voltage Protection Integrated
Battery Input Reverse Polarity Integrated
General Data
Operating Temperature Range -31°F~140°F (35°C~60°C)
Relative Humidity 0~95%
Operating Altitude (ft) ≤13123 ft (4000m)
Cooling Method Intelligent Fan
User Interface APP&LED(WiFi, Bluetooth)
Communication with BMS RS485; CAN
Communication with Meter RS485
Communication with EMS RS485 (Insulated)
Communication with Portal Wi-Fi; LAN (Optional)
Weight (lb) 70.5lb (32kg)
Dimension W×H×D -in (in) 16.3in * 31.1in * 6.9in (415mm * 791mm * 175mm)
Mounting Wall Bracket
Noise (dB) <45
Topology Transformerless
Night Power Consumption (W)
*3
<20
Protective Degree NEMA Type 4X
Certications & Standards
Grid Regulation
UL1741 SA, UL 1741 SB, California Rule 21, HECO Rule
14, IEEE 1547-2018, IEEE 1547a-2020, IEEE 1547.1-2020,
HECO SRD V2.0
Safety Regulation UL 1741, CSA C22.2 No. 107.1, UL 1998, UL991, UL1699B
EMC FCC part15 CLASS A&B
*1 Battery discharge/charge power limited by voltage.When A-BP is in microgrid application,
the maximum battery voltage is 405V.
*2 Can be reached only if battery power is enough.
*3 No Back-up Output.