OSHA TWA ACGIH TWACAS # Partial Chemical Name Other Limits
PEL: 1000 ppm TLV: 500 ppm
STEL: 750 ppm
67-64-1 Acetone {2-Propanone}
No data.
No data. No data.
872-50-4 N-Methyl-2-pyrrolidone
{2-Pyrrolidinone, 1-Methyl-;
1-Methylazacyclopentan-2-one}
No data.
For use in areas with inadequate ventilation or fresh air, wear a properly maintained and
properly fitted NIOSH approved respirator for organic solvent vapors.
For OSHA controlled work places and other regular users - Use only with adequate
ventilation under engineered air control systems designed to prevent exceeding the
appropriate TLV.
A dust mask does not provide protection against vapors.
Respiratory Equipment
(Specify Type):
Splash goggles.
Eye Protection:
Wear gloves with as much resistance to the chemical ingredients as possible. Glove
materials such as nitrile rubber, natural rubber, and neoprene may provide protection.
Glove selection should be based on chemicals being used and conditions of use.
Consult your glove supplier for additional information. Gloves contaminated with product
should be discarded and not reused.
Protective Gloves:
Various application methods can dictate use of additional protective safety equipment,
such as impermeable aprons, etc., to minimize exposure.
Other Protective Clothing:
Use process enclosures, local exhaust ventilation, or other engineering controls to
control airborne levels below recommended exposure limits.
Use only with adequate ventilation to prevent buildup of vapors. Do not use in areas
where vapors can accumulate and concentrate, such as basements, bathrooms or small
enclosed areas. Whenever possible, use outdoors in an open air area. If using indoors
open all windows and doors and maintain a cross ventilation of moving fresh air across
the work area. If strong odor is noticed or you experience slight dizziness, headache,
nausea or eye-watering -- STOP -- ventilation is inadequate. Leave area immediately
and move to fresh air.
Engineering Controls
(Ventilation etc.):
Wash hands thoroughly after use and before eating, drinking, smoking, or using the
restroom.
Do not eat, drink, or smoke in the work area.
Discard any clothing or other protective equipment that cannot be decontaminated.
Facilities storing or handling this material should be equipped with an emergency
eyewash and safety shower.
Work/Hygienic/Maintenance
Practices:
Licensed to W.M. Barr and Company: MIRS MSDS, (c) A V Systems, Inc.