SDS

04/17/2015Revision:
04/17/2015Printed:
Page: 3
Goof Off Stain Remover Outdoor
SAFETY DATA SHEET
03/20/2015Supersedes Revision:
5. FIRE FIGHTING MEASURES
Flash Pt:
NP
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH
approved or equivalent) and full protective gear.
Fire Fighting Instructions:
This product does not burn or support combustion.
If material is invovled in a fire, boiling liquid may emit vapors containing hydrogen
flouride fumes.
Flammable Properties and
Hazards:
Autoignition Pt:
No data.
Explosive Limits:
LEL: No data. UEL: No data.
Flammability Classification:
n/a
Non-combustible liquid - use extinguishing media for underlying cause of fire.
Suitable Extinguishing Media:
None known.
Unsuitable Extinguishing
Media:
6. ACCIDENTAL RELEASE MEASURES
Isolate the hazard area and deny entry. Keep unnecessary people away. Stay upwind,
out of low areas, and ventilate closed spaces before entering.
Small spills: Absorb the liquid with inert material, such as sand, earth, or other
noncombustible material and place into a compatible container for disposal.
Large spills: Dike far ahead of the spill for later disposal.
Steps To Be Taken In Case
Material Is Released Or
Spilled:
7. HANDLING AND STORAGE
Follow all MSDS/label precautions even after container is emptied because they may
retain product residues.
Keep container closed when not in use.
Precautions To Be Taken in
Handling:
Store in cool dry place. Avoid dry down to residue. Keep away from children.
Precautions To Be Taken in
Storing:
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
OSHA TWA ACGIH TWACAS # Partial Chemical Name Other Limits
PEL: 1 mg/m3 TLV: 1 mg/m3
STEL: 2 mg/m3
144-62-7 Oxalic acid {Ethanedioic acid}
No data.
PEL: 3 ppm CEIL: 3 ppm
7664-39-3 Hydrogen fluoride {Hydrofluoric acid;
Flouric acid}
No data.
A respiratory protection program that meets OSHA's 29 CFR 1910.134 and ANSI Z88.2
requirements must be followed whenever workplace conditions warrant a respirator's
use.
Under normal consumer use, respiratory protection is not normally required. Avoid
breathing high concentrations of vapors.
Respiratory Equipment
(Specify Type):
Safety glasses, with sideshields, chemical goggles or faceshields are recommended to
safeguard against potential eye contact.
Eye Protection:
Wear impermeable gloves, such as nitrile rubber to prevent skin contact.
Protective Gloves:
Various application methods can dictate the use of additional protective safety
equipment, such as impermeable aprons to minimize exposure.
Other Protective Clothing:
Licensed to W.M. Barr and Company: MIRS MSDS, (c) A V Systems, Inc.
GHS format