System Description

TEL : 886-3-327-3456
Page
81 of 173
FAX : 886-3-328-4978
Issued Date
:
Feb. 14, 2020
Form version: 181113
Report No. : FA9O2119
HSUPA Setup Configuration:
e. The EUT was connected to Base Station Agilent E5515C referred to the Setup Configuration.
f. The RF path losses were compensated into the measurements.
g. A call was established between EUT and Base Station with following setting * :
ix. Call Configs = 5.2B, 5.9B, 5.10B, and 5.13.2B with QPSK
x. Set the Gain Factors (β
c
and β
d
) and parameters (AG Index) were set according to each specific sub-test in
the following table, C11.1.3, quoted from the TS 34.121
xi. Set Cell Power = -86 dBm
xii. Set Channel Type = 12.2k + HSPA
xiii. Set UE Target Power
xiv. Power Ctrl Mode= Alternating bits
xv. Set and observe the E-TFCI
xvi. Confirm that E-TFCI is equal to the target E-TFCI of 75 for sub-test 1, and other subtest’s E-TFCI
h. The transmitted maximum output power was recorded.
Setup Configuration