SDS
Rechargeable Li-Ion Polymer Battery
Security level
Internal public
H043(1S1P) RECYCLED COBALT Battery Specification
Ver.
V1.4
飞毛腿公司机密,未经许可不得扩散。 第 12页, 共 25页
High Humidity&
High Temperature
/恒定湿热
The standard charged battery should be
stored in the oven with requirements of 90%-95%
relative humidity at 40±2℃ for 48 hours, after
finishing, inspect appearance and measure the
recovery capacity by standard charge/discharge
cycling after discharging with 0.2C to 3.0V cut-off at
23℃±2℃.
/电池按规定充电结束后,将电池放入 40℃±2℃,
相对湿度为 90%~95%的恒温恒湿箱中搁置 48h 后,
将电池取出在环境温度 23℃±2℃的条件下搁置,目
测电池外观;再以 0.2C 电流放电至 3.0V,然后以标
准充放电方式测量电池恢复容量。
Discharge time
≥180mins
/ 放电时间≥180 分钟
The battery should be no leakage.
电池应不漏液
The battery should be no distortion,
no rustiness, no leakage, no venting,
no fire or no explosion.
电池应不变形、不锈蚀、不泄露、
不泄气、不破裂、不起火和不爆炸。
5.3 PCM Specification/保护板规格
5.3.1
Function of PCM/
保护板参数
(Topr= -20~60
℃
)
Items
Unit
Min.
Typ
Max.
Remark
Primary Protection
1
st
Over charge detection voltage
/一段过充电保护电压
V
4.25
4.275
4.3
1
st
Over charge detection delay time
/一段过充电保护延迟时间
s
0.717
1.024
1.331
1
st
Overcharge release voltage
/一段过充保护恢复电压
V
4.215
4.275
4.3
1
st
Over discharge detection voltage
/一段过放电保护电压
V
2.26
2.3
2.34
1
st
Over discharge detection delay time
/一段过放电保护延迟时间
ms
67.2
96
124.8
1
st
Over discharge release voltage
/一段过放电保护解除电压
V
2.26
2.3
2.37
1
st
Discharge over current detection current 1
/一段放电过电流保护值
A
2.0
4.13
8.12
Charger release
/充电解除
1
st
Discharge over current detection delay time1
/一段放电过电流保护延迟时间
ms
7
10
13
1
st
Charge over current detection current
/一段充电过电流保护值
A
0.86
1.88
3.88
Load release
/放电解除
1
st
Charge over current detection delay time
/一段充电过电流保护延迟时间
ms
7
10
13