Safety data sheet

Amperex Technology Limited
新能源科技有限公司
3503,Wharf Cable TV Tower, 9 Hoi Shing Road,Tsuen Wan,N.T, HongKong China
香港新界荃湾海盛路 9 号有线电视大楼 35 楼 3 号单元
Tel
852-2498-0908 Fax
852-2498-1101 http://www.ATLbattery.com
MATERIAL SAFETY DATA SHEET
Issue: 2016-A Doc No.: 2016-A 176
_____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
------------------------------------------------------------------------------------------------------------------
ATL confident i a l
Page 4 of 17
8 People training: (a) turn on fans or portable fans for smoke escape. (b) wear the water
protection sets use water spray fire extinguishers dry by cloths with rubber gloves
insulated by plastic film. (c) neutralized by Ca(OH)
2
or NaOH for released electrolyte. (d) use
multimeter to measure voltage. Take care of the mistake.
5.3 Fire Extinguisher Flow Chart
1 Alarm if you found the smoking or burning.
2 Wear PPE. (Breath mask, face mask. If using water, PPE should include the raincoat,
galoshes, rubber gloves).
3 Turn Off power supply in devices or power supply.
4 Use any fire extinguishers for solid material fire, the recommended sequence was water or
mist water, sand, fire extinguisher blanket, CO
2
, powder.
5 Smoke Escape by turn on fans or open air environment.
6 Dry and neutralize. Drying by fans, Neutralization by Ca(OH)
2
powder if water was used.
6. Accidental Release Measures
On hand: Place material into suitable containers and call local fire/police department.
In water: Low electrical shock risk when EV or battery pack in water, GM also shared the
information. But H
2
gas was released by the electrolyzed water, you should keep good air flow to
avoid the H
2
gas accumulated to prevent hydrogen explosion in enclosed space. If possible, remove
from water and call local fire/police department.
Figure 1 water based fire extinguisher
(Could be used for 36KV electrical fire)
Figure 2 water sprayers to fire extinguisher
(Wear PPE to avoid electrical shock)