User Manual

8
Adaptation to a different
type of gas
• The procedure or adaptation of the cooker to another type of gas does not require
removal of the appliance from the worktop.
• Before adapting, disconnect the appliance from the power mains and close the gas
supply valve.
• Replace the existing nozzles for nominal thermal load with corresponding nozzles for
the new gas type and supplied provided (see table below).
• After finishing this sequence, replace the old setting label with the new one provided
for the new injectors.
Adjustment elements
To leave the adjustment elements accessible, please observe the following instructions:
• Remove the support grid and burner covers with respective crowns.
• In double burners, adjustment elements are accessible behind the main nozzle
protective plate.
• Remove the control knobs, including the gaskets.
Gas valve
Minimum thermal load regulation valve
Minimum flow
adjustment
Instructions for town (G110, G120, G150.1) and methane gas (G20, G25)
1. Light the burner and bring it to the minimum position.
2. Remove the gas tap knob and turn the adjustment screw on the side of the tap rod:
anti-clockwise to increase the gas flow
clockwise to reduce the gas flow
until a regular minimum flame is obtained.
3. Re-assemble the knob and verify burner flame stability (when quickly rotating the
hand from maximum to minimum position the flame must not shut off).
4. Repeat the operation on all gas taps.
Instructions for liquid gas (LPG: G30, G31)
Tighten the screw on the side of the tap, rod clockwise completely.
Warning: these tasks may only be carried out by a qualified technician, authorized by the gas distributing
company or authorized service center!
TECHNICAL INFORMATION
GKTG6SY
Operating voltage
220-240 V~ ; 50/60 Hz
Category gas usage Natural gas 1.0 kPa or Universal LPG 2.75
Qn
GAS HOB
28,08 MJ/h
BURNERS
Burner Qn
BURNER
Min-Max pan Ø
A
Auxiliary 3,60 MJ/h
12 - 18 cm
SR
Semirapid 6,30 MJ/h
18 - 22 cm
MW
Mini-Wok 11,88 MJ/h
22 - 26 cm