Operating Instructions and Installation Instructions

436556
‘’ The appliances are suitable for photovoltaic electrical
power under the condition that electrical voltage will
be 220VAC - 240VAC with semi tonic frequency 50Hz
in order the appliance to operate properly (alternative
a generator can be used with the same technical
characteristic).’’
• Incorrect connection may destroy parts of the appliance,
making the warranty void.
• Before connecting the appliance, make sure the voltage
indicated on the rating plate is consistent with the
voltage in your home network. Connection voltage
(230 V through N) should be checked by a qualifi ed
technician using a corresponding measuring device!
• Connection cable on the back of the appliance should
be led in such way that it does not touch the appliance
back wall, as this part will get very hot during operation.
NOTE:
Connection bridges are already installed on their
respective places on the clip. Screws of the connection
terminals are open, which means they do not have to be
unfastened or unscrewed any further. When fastening the
screws, you may hear a slight ‘click’, which means that the
screws should be fastened / screwed in completely.
The following can be used for connection:
• Type H05 RR-F 4×1.5 rubber connection cables with a
green-yellow protective wire,
• Type H05 VV-F 4x1,5 PCV insulated connection cables
with yellow-green protective wire, or other equivalent or
superior grade cables.
Connection diagram
24