SDS

Gorilla Glue SDS 05/21/2015 Page 8 of 11
Safety Data Sheet
-
Gorilla
Glue
Date Revised: 05/21/2015
Date Issued: 05/21/2015
FOR CHEMICAL EMERGENCY:
During Business Hours: (800) 966-3458 | Outside Business Hours: (800) 420-7186
Version
:
1.0
According to Federal Register /
Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
Polyisocyanate Prepolymer based on MDI (67815-87-6)
ATE US (dust, mist) 1.50 mg/l/4h
Polymeric Diphenylmethane Diisocyanate (pMDI) (9016-87-9)
LD50 Oral Rat 49000 mg/kg
LD50 Dermal Rat > 9400 mg/kg
LC50 Inhalation Rat 490 mg/m³ (Exposure time: 4 h)
4,4'-Methylenediphenyl diisocyanate (101-68-8)
LD50 Oral Rat 31600 mg/kg
LD50 Dermal Rabbit > 9400 mg/kg
ATE US (dust, mist) 1.50 mg/l/4h
Diphenylmethane Diisocyanate (MDI) Mixed Isomers (26447-40-5)
LD50 Oral Rat > 7400 mg/kg
LD50 Dermal Rabbit > 6200 mg/kg
LC50 Inhalation Rat 0.369 mg/l/4h
Additive (Trade Secret)
ATE US (dermal) 1,100.00 mg/kg body weight
Polymeric Diphenylmethane Diisocyanate (pMDI) (9016-87-9)
IARC Group 3
4,4'-Methylenediphenyl diisocyanate (101-68-8)
IARC Group 3
Diphenylmethane Diisocyanate (MDI) Mixed Isomers (26447-40-5)
IARC Group 3
SECTION 12: ECOLOGICAL INFORMATION
Toxicity
Ecology - General: Ecotoxicity data based on polymeric MDI (a mixture of monomers and higher molecular weight oligomers).
Diphenylmethane Diisocyanate (MDI) Mixed Isomers (26447-40-5)
NOEC (acute) >= 1000 mg/kg (Exposure time: 14 Days - Species: Eisenia foetida [soil dry weight])
Persistence and Degradability
Gorilla Glue
Persistence and Degradability Biodegradation for this product was 0%, exposure time: 28 days, i.e. not degradable.
Biodegradation 0 % after 28 days
Bioaccumulative Potential
Gorilla Glue
BCF fish 1 < 1 Oncorhynchus mykiss (rainbow trout), Exposure time: 112 d (does not bioaccumulate)
Diphenylmethane Diisocyanate (MDI) Mixed Isomers (26447-40-5)
BCF Fish 1 3 - 14
Log Pow 4.5
Mobility in Soil
Not available
Other Adverse Effects
Other Information: Avoid release to the environment.
SECTION 13: DISPOSAL CONSIDERATIONS
Sewage Disposal Recommendations: Do not dispose of waste into sewer.
Waste Disposal Recommendations: Dispose of waste material in accordance with all local, regional, national, provincial, territorial
and international regulations.