According to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
Boiling Point
:
Not available
Flash Point
:
Not available
Auto-ignition Temperature
:
Not available
Decomposition Temperature
:
Not available
Flammability (solid, gas)
:
Not available
Lower Flammable Limit
:
Not available
Upper Flammable Limit
:
Not available
Vapor Pressure
:
Not available
Relative Vapor Density at 20 °C
:
Not available
Relative Density
:
Not available
Specific Gravity
:
1 g/cm³ (+/- 0.1) for Tough & Clear; 0.75 g/cm³ (+/- 0.1) for Heavy Duty
Solubility
:
Water: Negligible
Partition Coefficient: N-Octanol/Water
:
Not available
Viscosity
:
Not available
Explosion Data Sensitivity to Mechanical Impact
:
Not expected to present an explosion hazard due to mechanical impact.
Explosion Data Sensitivity to Static Discharge
:
Not expected to present an explosion hazard due to static discharge.
SECTION 10: STABILITY AND REACTIVITY
Reactivity: None known.
Chemical Stability: Stable under recommended handling and storage conditions (see section 7).
Possibility of Hazardous Reactions: Hazardous polymerization will not occur.
Conditions to Avoid: Direct sunlight. Extremely high or low temperatures.
Incompatible Materials: Strong acids, strong bases, strong oxidizers.
Hazardous Decomposition Products: Carbon oxides (CO, CO
2
).
SECTION 11: TOXICOLOGICAL INFORMATION
Information on Toxicological Effects - Product
LD50 and LC50 Data: Not available
Skin Corrosion/Irritation: Not classified
pH: Not applicable
Serious Eye Damage/Irritation: Not classified
pH: Not applicable
Respiratory or Skin Sensitization: Not classified
Germ Cell Mutagenicity: Not classified
Teratogenicity: Not available
Carcinogenicity: Not classified
Specific Target Organ Toxicity (Repeated Exposure): Not classified
Reproductive Toxicity: Not classified
Specific Target Organ Toxicity (Single Exposure): Not classified
Aspiration Hazard: Not classified
Symptoms/Injuries After Inhalation: Prolonged, repeated inhalation of adhesive may cause dizziness and drowsiness.
Symptoms/Injuries After Skin Contact: Repeated or prolonged skin contact may cause irritation.
Symptoms/Injuries After Eye Contact: Contact may cause irritation due to mechanical abrasion.
Symptoms/Injuries After Ingestion: Ingestion is likely to be harmful or have adverse effects.
Chronic Symptoms: Repeated or prolonged skin contact may cause irritation.
Information on Toxicological Effects - Ingredient(s)
Acute Toxicity: Not classified