Instruction Manual

OM−02818 VG SERIES
PAGE B − 6 INSTALLATION
MISALIGNED:
SHAFTS
NOT PARALLEL
MISALIGNED:
SHAFTS
NOT IN LINE
ALIGNED: SHAFTS
PARALLEL AND
SHEAVES IN LINE
Figure 3C. Alignment of V-Belt Driven Pumps
Tighten the belts in accordance with the belt manu-
facturer’s instructions. If the belts are too loose,
they will slip; if the belts are too tight, there will be
excessive power loss and possible bearing failure.
Select pulleys that will match the proper speed ra-
tio; overspeeding the pump may damage both
pump and power source.
Do not operate the pump without the
guard in place over the rotating parts.
exposed rotating parts can catch cloth-
ing, fingers, or tools, causing severe in-
jury to personnel.