Blood Glucose Meter User Manual

38 GOSSEN METRAWATT GMBH
12 Storage in PSI Module (Feature E01)
and Database Operations (Feature KB01 or DBmed option)
12.1 Storing Measurement Data in the PSI Module
Upon completion of a measurement – „Test passed/Test failed“ is shown
on the display – you can save the measurement data to the memory of
the PSI module.
Press the STORE key at the PSI module to this end.
A text entry field is shown.
You may now enter your comments on the measurement and/or an
identification number.
Press the STORE key once more to save the measurement data and
your comments.
The message: „Data are stored“ is displayed.
A detailed description is given in the operating instructions of your PSI
module under chapter „How to display, print and store protcol“.
12.2 Database Operations
12.2.1 Setting Up Test Sequences with PC Software
This function must be activated with the help of upgrade software, e.g.
the Z853H program.
Up to 99 test sequences can be uploaded for each of the selector switch
positions from a PC via the serial port at the SECUTEST
®
SII test instru-
ment. After testing has been performed, the test results are saved to the
same database, if a PSI module has not been connected. The maximum
possible sum of test sequences and test results is 127.
Test results are stored to the PSI module if one has been connected.
The database can be used in different ways:
(see also chapter 11.2 on page 27)
1. Stored test results can be displayed
(select the ID no. and then activate the “from database” function).
The desired test sequence can be selected with the scroll keys.
2. If “ID no. = test sequence” has been activated (X), the first two
characters of the ID number determine the test sequence.
Example: ID number = 037890sk3r
Test sequence number 03 is executed.
Test sequence 03 is the test sequence which appears at the
third position from the top of the list.
If this number does not exist, the default sequence is executed.
3. Executed test sequences are stored to memory at the instrument as
test results. The test results can also be displayed at a later point in
time with the “test sequence settings” submenu in the “general setup”
menu.
Note
The database can only be generated or deleted with the help of
a PC with a terminal program, or appropriate application
software.
12.2.2 Storing Test Results to the SECUTEST
®
SII
This function must be activated with the help of upgrade software, e.g.
the Z853H program.
If no PSI module has been connected, up to 99 reports can be stored to
the test instrument. The reports can be viewed as required at the instru-
ment and can be printed out, for example with the help of DA-II software
or a terminal program.
The reports are sorted by time and date and are displayed with the ID
number. If no ID number was assigned, date and time are automatically
saved instead.
13 Remote Control (Feature KD01 or SK5 Option)
This function must be activated with the help of upgrade software, e.g.
the Z745K program.
The protective conductor measurement is expanded to include the
function: “automatic recognition of measuring point change”.
During protective conductor measurement, the instrument recognizes
whether or not the probe is in contact with the protective conductor, and
indicates these two possible conditions by means of different acoustic
signals.
This function is helpful if several protective conductor connections need to
be tested. The function can be activated with the “auto measuring point”
function in the “test sequence setup” menu (see “changes to the switch
position menu” above).