Datasheet
METRAHIT⏐X-TRA⏐OUTDOOR⏐TECH⏐PRO⏐BASE
TRMS Digital Multimeters
3-349-350-03
5/8.08
GMC-I Gossen-Metrawatt GmbH 
DQS Certified per
DIN EN ISO 9001:2000
QUALITY MANAGEMENT SYSTEM
reg. no.1262
Calibration Certificate included
 *
Applications
The multimeter is suitable for universal use in electrical 
engineering, electrical installation, laboratory applications, 
telecommunication, training etc.
The instrument can be used in the field and is equipped with
internal, mains-independent supply power.
Features
Three Connector Jacks with Automatic Blocking Sockets (ABS) 
1)
All current ranges are implemented via a single connector jack 
which prevents any possibility of operator error. 
Beyond this, the automatic blocking sockets prevent incorrect 
connection of the measurement cables, as well as selection of the 
wrong measured quantity. Danger to the user, the instrument and 
the device under test resulting from operator error is thus ruled 
out.
1)
 Patented (patent no. DE 10 2005 062 624)
Overload Protection
The instrument is safeguarded for up to 1000 V in all measuring 
functions by overload protection. Voltages of greater than 1000 V 
and current of greater than 10 or 16 A are indicated acoustically. 
Dangerous contact voltages are indicated when the 1 kHz low-
pass filter is activated. 
The FUSE display appears at METRAHIT⏐X-TRA, 
METRAHIT⏐O
UTDOOR, METRAHIT⏐TECH and METRAHIT⏐PRO instru-
ments in order to indicate that the fuse for the current measuring 
input has blown.
RMS Value with Distorted Waveshape
The utilized measuring method allows for waveshape 
independent RMS measurement (TRMS AC and AC+DC) for 
voltage and current (METRAHIT⏐X-
TRA⏐OUTDOOR up to 20 kHz).
Activatable Filter for V AC Measurement
A 1 kHz low-pass filter can be activated if required, for example 
when measuring motor voltage at electronic frequency 
converters. The input signal is checked by a voltage comparator 
for dangerous voltages as long as the low-pass filter is activated.
Measuring 5 V Square-Wave Signals with the METRA
HIT
⏐
X-
TRA
⏐
O
UTDOOR
This function makes it possible to test circuits and transmission 
cables by measuring the frequency and the keying ratio of pulses 
with amplitudes of 2 to 5 V and frequencies of 100 Hz to 1 MHz.
Analog Scale for Quick Trend Display – Bar Graph or Pointer
The analog scale (with additional negative range for zero-
frequency quantities) allows for faster recognition of measured 
value fluctuation than is possible with a digital display.
The instrument can be switched back and forth between bar 
graph and pointer display.
* The approval mark issued by the VDE test authority applies to the 
following multimeters:
 METRAHIT⏐X-TRA⏐TECH⏐PRO⏐BASE
• Digital Hand-Held Multimeters with RMS Measurement 
V
AC TRMS
, V
AC+DC TRMS
, V
DC
, Hz (V), Hz (A), 
Ω
, V , °C/°F (TC)
• 4½-place display (11,999 digits), with display illumination
METRAHIT⏐B
ASE
• Current measurement via clip-on current sensors: 
The transformation factor is adjustable from 1 mV:1 mA to 
1 mV:1 A and is accounted for by the display.
METRAHIT⏐T
ECH
• Direct Current measurement with increased accuracy and 
Current measurement, via clip-on current transformer and sensors
• Broad range capacitance measurement
METRAHIT⏐X-TRA⏐OUTDOOR⏐TECH⏐PRO
• Additional “low-resistance” (1 M
Ω
) alternating voltage measurement 
• 1 kHz / -3 dB low-pass filter can be activated
METRAHIT⏐X-TRA⏐OUTDOOR
• Direct current measurement from 10 nA to 10 A, 16 A for short periods
• Temperature measurement with Pt100(0) resistance thermometer
• Broad range capacitance measurement
• Frequency and keying ratio measurement at 2 to 5 V signals or up to 1 MHz
• Data memory and bidirectional infrared interface
METRAHIT⏐O
UTDOOR
• Extremely rugged, dust and water-proof variant with 
IP 65 protection