User Manual

54 GMC-I Gossen-Metrawatt GmbH
Technical Data
8 Technical Data
1)
Values of less than 200 digits are suppressed in the mV range.
2)
At 0 ° ... + 40 °C
3)
Display up to max. 5.1 V, “OL” in excess of 5.1 V.
4)
Residual value deviates within 1 ... 30 d from the zero point due to TRMS converter
when probe tips are short-circuited. See frequency influence on page 56.
5)
Switch-off time/Cool-down time > 30 min and T
A
40 °C
Meas.
Function
Measuring Range
Resolution at Upper
Range Limit
Input Impedance
Intrinsic Errorunder Reference Conditions
Overload Capacity
2)
±(... % rdg. + ... d) ±(... % rdg. + ... d) ±(... % rdg. + ... d)
11,999 1199
~ /
~
4)
4)
Value Time
V
100 mV 10 μV 9MΩ≥ 9MΩ // < 50 pF 0.09 + 5 with ZERO 1 + 30 (> 300 d)
1)
1 + 30 (> 300 d)
1)
1000 V
DC
AC
RMS
sine
continuous
1 V 100 μV 9MΩ≥ 9MΩ // < 50 pF 0.05 + 3 0.5 + 9 (> 200 d) 1 + 30 (> 300 d)
10 V 1 mV 9MΩ≥ 9MΩ // < 50 pF 0.05 + 3 0.5 + 9 (> 200 d) 1 + 30 (> 300 d)
100 V 10 mV 9MΩ≥ 9MΩ // < 50 pF 0.05 + 3 0.5 + 9 (> 200 d) 1 + 30 (> 300 d)
1000 V 100 mV 9MΩ≥ 9MΩ // < 50 pF 0.09 + 3 0.5 + 9 (> 200 d) 1 + 30 (> 300 d)
Voltage drop, approx. at upper range limit
~
4)
4)
A
X-
TRA
OUTDOOR
PRO
100 μA 10 nA 12 mV 12 mV 0.5 + 5 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
0.2 A
continuous
1 mA 100 nA 120 mV 120 mV 0.5 + 3 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
10 mA 1 μA 16 mV 16 mV 0.5 + 3 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
100 mA 10 μA 160 mV 160 mV 0.5 + 3 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
1 A 100 μA 40 mV 40 mV 0.9 + 10 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
10 A: 5 min
5)
16 A: 30 s
5)
10 A 1 mA 600 mV 600 mV 0.9 + 10 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
A
T
ECH
10 mA 1 μA 16 mV 16 mV 0.1 + 5 1 + 10 (> 200 d) 1.5 + 30 (> 200 d)
0.2 A
continuous
100 mA 10 μA 160 mV 160 mV 0.1 + 5 1 + 10 (> 200 d) 1.5 + 30 (> 200 d)
1 A 100 μA 40 mV 40 mV 0.9 + 10 1 + 10 (> 200 d) 1.5 + 30 (> 200 d)
10 A: 5 min
5)
16 A: 30 s
5)
10 A 1 mA 600 mV 600 mV 0.9 + 10 1 + 10 (> 200 d) 1.5 + 30 (> 200 d)
Factor: 1:1/10/100/1000
Input Input impedance
A
T
ECH
0.1/1/10/100 A 100 mA
Current measuring input
(A socket)
Specification see current ranges A (T
ECH)
Measuring input
1/10/100/1000 A 1 A 0.2 A continuous
10 A: 5 min
10/100 /1 00 0 / 10000 A
10 A plus clip-on current sensor error
A
T
ECH
BASE
0.1/1/10/100 A 100 mV
Voltage measurement input
T
ECH: (V socket) Ri =1 MΩ/9 MΩ
B
ASE: ( V socket) Ri ~1 MΩ
±(0.5% rdg. + 10 d)
±(1% rdg. + 30 d)
> 300 d
±(1% rdg. + 30 d)
> 300 d
Measurement input
1/10/100/1000 A 1 V
1000 V RMS Max. 10 s
10/100 /1 00 0 / 10000 A
10 V Plus clip-on current sensor error
Open-circuit voltage
Meas. curr. @ range limit
±(... % rdg. + ... d)
Ω
100 Ω 10 mΩ < 1.4 V Approx. 300 μA 0.2 + 5
with active ZERO function
1000 V
DC
AC
RMS
sine
Max. 10 s
1kΩ 100 mΩ < 1.4 V Approx. 250 μA 0.2 + 5
10 kΩ 1 Ω < 1.4 V Approx. 100 μA 0.2 + 5
100 kΩ 10 Ω < 1.4 V Approx. 12 μA 0.2 + 5
1MΩ 100 Ω < 1.4 V Approx. 1.2 μA 0.2 + 5
10 MΩ 1kΩ < 1.4 V Approx. 125 nA 0.5 + 10
40 MΩ 10 kΩ < 1.4 V Approx. 20 nA 2.0 + 10
100 Ω —0.1Ω Approx. 8 V Approx. 1 mA const. 1 + 5
5.1 V
3)
1 mV Approx. 8 V Approx. 1 mA const. 0.5 + 3
X
-
TRA
/O
UTDOOR
PRO
TECH