User Manual

14 GMC-I Gossen-Metrawatt GmbH
Operating Overview – Connections, Keys, Rotary Switch, Symbols
Symbols of Rotary Switch Positions
Switch
FUNC
Display Measuring Function
METRA
HIT
X-
TRA/
OUTDOOR
METRAHIT
T
ECH
METRAHIT
P
RO
METRAHIT
B
ASE
V~ 0/4 V~ AC TRMS Alternating voltage, TRMS AC, full bandwidth ••••
Hz (V) 1 Hz ~ AC Voltage frequency, full bandwidth ••••
V~ 2 V Fil ~ AC TRMS Alternating voltage, TRMS AC, with low-pass (1 kHz) •••
Hz (V) 3 Hz Fil ~ AC Voltage frequency, with low-pass (1 kHz) •••
V~ 1 M
Ω 0/4 V~ AC TRMS Alternating voltage, TRMS AC, full bandwidth, input 1 MΩ•
V~ 1 V Fil ~ AC TRMS Alternating voltage, TRMS AC, up to 1 kHz, input 1 MΩ•
Hz (V) 2 Hz Fil ~ AC Voltage frequency, up to 1 kHz, input 1 MΩ•
Hz (V) 1 M
Ω 3 Hz ~ AC Voltage frequency, full bandwidth, input 1 MΩ•
V 0/2 V DC Direct voltage ••••
V 1 V DC AC TRMS Pulsating voltage, TRMS ( ) ••••
MHz 0/2 MHz (High) frequency @ 5 V~ ———
% 1 % Keying ratio @ 5 V~ ———
Ω
Ω (Direct current) resistance ••••
0/2 Ω Continuity testing Ω with acoustic signal ••••
1
V DC Diode voltage ••••
Temp TC 0/2
°C Typ-K
Temperature thermocouple Type K ••••
Temp RTD 1 °C Pt100/1000 Temperature with resistance thermometer Pt100/Pt1000 ———
nF Capacitance ••——
A 0/2 A DC Direct current value •••
A 1 A DC AC TRMS Pulsating current value, TRMS AC DC •••
A~ 0/2 A~ AC TRMS Alternating current value, TRMS AC •••
Hz (A) 1 Hz ~ AC Current frequency •••
0/2 A DC Direct current value with AC DC clip-on current sensor 1 V:1/10/100/
1000 A
1 A DC AC TRMS
Pulsating current value, TRMS, with AC DC clip-on current sensor, see above
0/2 A~ AC TRMS
Alternating current strength, TRMS, with clip-on current sensor, see above
Hz ( ) 1 Hz ~ AC Current frequency
1kHz
1kHz
1kHz
1kHz
V
ACDC
V
AC
2
V
DC
2
+=
A
A
A
A