Operating Instructions DIGISIX Exposure meter for ambient light 15122 1/06.
Diffuser Setting window Setting ring: TIME/ Shutter speed Socket for tripod Setting ring: Aperture/ f-stops Camera mounting clip (accessory) Display Measuring key Function button Eyelet for carrying strap 2 Battery compartment GOSSEN Foto- und Lichtmeßtechnik
Content 1 1.1 1.2 The functioning of the Digisix ..... 4 Preparation and self-test ................ 4 Incident light and reflected light measuring mode 5 1.3 Duration of read-out in display ....... 5 2 Functions of the Digisix .............. 6 2.1 Setting the film speed ..................... 6 2.2 Exposure measuring ...................... 7 2.2.1 Read-out of the values measured .. 7 2.2.2 Taking a measurement outside the measuring range............8 2.3 Contrast measurements ................. 9 2.
1 The functioning of the Digisix 1.1 Preparation and self-test Battery The Digisix is powered by a 3 V Lithium battery, type CR 2032. When the battery is running low, the signal BAT appears in the display. – The battery should be replaced as soon as possible. When BAT is shown alone in the display, the battery will need to be replaced before further measurements are possible. – To replace the battery, pull out the battery compartment placed under the eyelet for the carrying cord.
1.2 Incident light and reflected light measuring mode The measurement is taken from the position Incident light method of the camera towards the subject. In this For the incident mode, the diffusor is to be method, only the light reflected from the shifted to the left and placed in front of the subject is detected by the meter. Therefore, measuring aperture. Taking measurements the measuring values always depend on the using the incident light mode in particular reflection capacity of the subject.
2 Functions of the Digisix Press the function button for selecting the individual functions of the Digisix. Each time the button is pushed, the next function will be activated. The display panel will show the functions in the following sequence.: • • • • • Exposure metering Timer Watch Alarm clock Temperature The next function will only be activated after the Function button has been released.
– Confirm the speed you selected by pushing the Function button until the OK-signal sounds and the Digisix returns to the function "EXPOSURE". The film speed is shown in the upper right corner of the display. 2.2 Exposure measuring – Use the Function button to select the function Exposure Measuring. – The measurement is taken by briefly pressing down the measuring key M. 2.2.1 Read-out of the values measured The EV value measured will appear in the display.
– Transfer that EV value from the display to the setting window in the calculator rings and align it opposite the setting mark in the setting window. – All the suitable combinations of aperture (f-stops) - t (shutter speed) can now be seen at the upper part of the circular scales (see previous example). 2.2.2 Taking a measurement outside the measuring range The DIGISIX will not produce any useable readings outside its measuring range: in the display Eu (too dark) or En (too bright) will appear.
2.3 Contrast measurements – Use the Function button to select the function "EXPOSURE". – Keep the measuring key M pressed down and the meter will switch over to contrast measurement. Continue holding down the key to measure various other areas in the subject. In the display, the difference between the individual results of the additional measurements and the first measuring value will be indicated in EV. A new metering will be made approx. 2 times a second. 2.
The EV in the display will blink to remind you that the standard factory calibration has been changed. Input of the correction in 1/3-stops in the range of ± 3 EV. For cancelling the correction value, remove the battery from the compartment for a moment and then put it back again. In case of over-exposure a positive correction, in case of under-exposure a negative correction value should be set. GOSSEN Foto- und Lichtmeßtechnik 2.
– Enter the "seconds" of the desired length of time. Confirm by pressing and holding the function button until the OK-signal will sound. The timer will now be in the Start/ Stop function. – Push the key M to start the timer. The display will show the remaining time of the count-down. In addition to that, during the last 10 seconds of the countdown, interrupted signals can be heard. At the end of the set time, a continued signal will sound.
2.6 Watch/Alarm clock WATCH – Setting the time – Use the function button to select the function WATCH and hold the key down until the OK-signal will sound. 12/24 will flash. – Use the key M to set the hours and confirm with the function button. The read-out "minutes" in the display will flash. – Use the key M for setting the minutes. To confirm settings hold down the function button until the OK-signal is heard. – With the function button select either 12 hours (AM/PM) – 24 hour display.
ALARM CLOCK – Use function button to enter the function "ALARM CLOCK" and hold it pressed down until the OK-signal will sound. The time of the alarm clock is set in the same way as the watch. – Hold the function button until the OK-signal sounds. – The alarm is activated or deactivated with the measuring button. – When the alarm is activated it is shown in the display with a bell symbol. – When the alarm is sounded it will sound each second for 1 min.
2.7.1 Min./Max. temperatures When repeatedly pressing the measuring key, the minimum (Lo) and maximum (Hi) temperature values will be indicated. The minimum and maximum values indicated are those that have been measured since the last cancellation operation. 3 Service and repairs In the event that your DIGISIX is not working to your complete satisfaction, please send it to: GOSSEN Foto- und Lichtmeßtechnik GmbH Thomas-Mann-Str. 16-20 D - 90471 Nürnberg or to the GOSSEN agency in your country. The min.
4 Technical data Exposure meter Measuring modes Light sensor Measuring range (when ISO 100/21°) Ambient light Incident light method Reflected light method Contrast measurem. sbc photo diode EV 0 to 18 Shutter speeds 1/2000 s to 4 min Apertures 1 to 32 Calibration adjustments ± 3.0 Film speeds Measuring angle reflected light mode Timer 0 sec to 30 min Watch adjustable to 12 hrs (AM + PM) or 24 hrs Accuracy 5 min / year Thermometer adjustable to °C/ °F Measuring range –15 ... 70 °C or 5 .
Battery 1 x 3 V Lithium battery CR 2032 Operating temp. –10 °C ... 60 °C Dimensions 75 x 50 x 23 mm Weight 40 g incl. battery Accessories incl. Battery, carrying case, cord, instruction manual Optional accessory Mounting clip for camera shoes Order code V069A Printed in Germany • Subject without notice GOSSEN Foto- und Lichtmeßtechnik GmbH Thomas-Mann-Str. 16-20 D-90471 Nürnberg Phone: +49 911 / 8602-181 Fax: +49 911 / 8602-142 http://www.gossen-photo.