Datasheet

audio
GAC-2/1
Professional installation cable with small diameter
The European Choice in Professional Audio Wiring double shieldeddouble shielded
4
Construction
Technical Specifications
Ordering Data
Order No. Type ø mm Colour Spool Size Weight /Spool Shipping Unit
10301 GAC-2/1 3.3 grey 300 m 6.3 kg 4 x 300 m
10302 GAC-2/1 3.3 grey 800 m 17.0 kg 2 x 800 m
1 Jacket PVC, ø 3.3 mm, grey
2 Shield No. 1 Bare OF copper wires (0.10 mm), 100% coverage
3 Shield No. 2 Bare OF copper wires (0.10 mm), 100% coverage
4 Insulation PE, ø 1.15 mm
5 Conductor Stranded bare OF copper wires, 25x0.1 mm (0.20 mm²)
Conductor resistance < 92 Ohm /km
Shielding resistance < 20 Ohm /km
Capacitance at 800 Hz cond /cond < 75 nF /km
Capacitance at 800 Hz cond /shield < 130 nF /km
Characteristic impedance at 20 kHz 145 Ohm
Test voltage cond /cond 500 V eff.
Test voltage cond /shield 2000 V eff.
Operating voltage low voltage
Temperature range (flex) - 5° to +50° C
Temperature range (fix) -30° to +70° C
Professional installation cable with small diameter, PE-insulation for low capacity. Ideal for fixed installations and
rack-wirings. The same construction is used as single element on our range of analog multipair cables.
audio
GAC-2/foil
Installation cable
The European Choice in Professional Audio Wiring double shieldeddouble shielded
5
ConstructionTechnical Specifications
Ordering Data
Order No. Type ø mm Colour Spool Size Weight /Spool Shipping Unit
10201 GAC-2/foil 3.0 black 800 m 16.3 kg 2 x 800 m
10202 GAC-2/foil 3.0 black 300 m 5.1 kg 4 x 300 m
1 Jacket PVC, ø 3.0 mm, black
2 Shield Aluminium-Polyester foil
3 Drain wire Stranded OF tinned copper wires, 7x0.20 mm (0.22 mm²)
4 Insulation (cond.) PE, ø 1.1 mm, twisted, black and red conductors
5 Conductor Stranded OF tinned copper wires, 7x0.20 mm (0.22 mm²)
Conductor resitance < 85 Ohm /km
Shielding resistance < 65 Ohm /km
Capacitance cond /cond < 75 nF /km
Capacitance cond /shield < 140 nF /km
Test voltage cond /cond 500 V eff.
Test voltage cond /shield 1500 V eff.
Temperature range (flex) - 5° to +50° C
Temperature range (fix) -30° to +70° C
Foil shielded installation cable using 7 x 0.20 mm tinned wires for IDT. Designed for wiring balanced audio signals
in a metal environment. Aluminium foil is melt with the PVC-jacket and will come off automatically when the PVC-
jacket is removed.
The twisting of each of the 7 strands is so tight that once peeling the insulation off, the strands do not come apart