User Manual

SHUTDOWN
1. Slowly close discharge valve.
2. Shut down and lock out driver to prevent
accidental rotation.
s
! WARNING
When handling hazardous and/or toxic fluids,
skin, eye and respiratory protection are required.
If pump is being drained, precautions must be
taken to prevent injury or environmental
contamination. Pumpage must be handled and
disposed of in conformance with applicable
environmental regulations.
FINAL ALIGNMENT
1. Run the unit under actual operating conditions for
a sufficient length of time to bring the pump and
driver up to operating temperature.
2. Check and reset alignment per alignment
procedure outlined earlier.
3. Reinstall coupling guard per instruction in
appendix.
22 3296 M Group 6/05