Owner manual

Commissioning, Startup, Operation, and Shutdown
Stage length Pump size Temperature threshold for hot
doweling
8 3x4-8 N/A
3x4-9 360°F (182°C)
3x6-9/10 380°F (193°C)
4x6-10 330°F (166°C)
4x6-10D 310°F (154°C)
4x6-11
4x6-11D 280°F (138°C)
6x8-11
6x8-11D 250°F (121°C)
6x8-13
6x8-14 230°F (110°C)
9 3x4-8 370°F (188°C)
3x4-9 340°F (171°C)
3x6-9/10 360°F (182°C)
3x4-12.5 290°F (143°C)
4x6-12
4x6-10
4x6-10D
4x6-11
4x6-11D 260°F (127°C)
6x8-11
6x8-11D 240°F (116°C)
10 3x4-8 350°F (177°C)
3x4-9 310°F (154°C)
3x6-9/10 330°F (166°C)
3x4-12.5 270°F (132°C)
4x6-12
4x6-10
4x6-10D
4x6-11
4x6-11D 250°F (121°C)
6x8-11
6x8-11D 220°F (104°C)
11 3x4-8 330°F (166°C)
3x4-9 300°F (149°C)
3x6-9/10
4x6-10 270°F (132°C)
3x4-12.5 250°F (121°C)
4x6-12
4x6-10D
4x6-11
4x6-11D 240°F (116°C)
12 3x4-8 310°F (154°C)
3x4-9 280°F (138°C)
3x6-9/10
3x4-12.5 240°F (116°C)
4x6-12
4x6-10
4x6-10D
4x6-11
4x6-11D 220°F (104°C)
13 3x4-8 290°F (143°C)
3x4-9 260°F (127°C)
3x6-9/10
3x4-12.5 220°F (104°C)
4x6-12
Model 3600, API 610 8th, 9th, 10th & 11th Editions (ISO 13709) Installation, Operation, and Maintenance Manual 49