Install Instructions

Warning device alarms
Table 1: Model information
Alarm
order no.
Agency
listing
NEMA
rating
3
Float
switch
included
Float
switch
length
Power
cord
length
Audible
alarm
type/db at
10’
Primary
power
Hertz Voltage to
float
switch
Battery
backup
alarm
Additional
features
A4–2 UL, CSA
N1
10’
6’
Horn / 87
120 VAC
60 9 VDC Yes
TAN1M* UL CSA
15’
Horn / 88 50/60 12 VAC No
TAN3M* UL, CSA N3R
N/A
Horn / 85
120 VAC No
TAN4M* N4X Horn / 88
TAABW FCC
N1 Yes
10’
6’ Horn / 87
60
9 VDC Yes
1
TAABWUL
FCC
TAABP
10’
2
2
LAN1 UL, CSA
Order
separately
N/A
Bell / 88
120 VDC No
LAN4 UL, CSA N4X No Horn / 95
@ 2’
* M = Mechanical SignalMaster Switch
1
This device is wireless and will transmit a signal up to 150’ between the transmitter and the alarm, it requires line of sight clearance between
the transmitter and the alarm panel, i.e. (no hills in between).
2
The TAABP has a 120V, NEMA 5–15R, 13.8 Amp Max. receptacle on the bottom to accommodate a pump plug.
3
N1 = indoor, N3R = raintight (outdoor), N4X = watertight (outdoor) and Corrosion resistant (fiberglass).
Battery backup sump pump
Specifications:
12 volt pump
Float switch
10 amp battery charger
Check valve
Pipe fittings
Battery box is 7.5” W, 14.5” L, 8” D and is sized for Group 24–30 batteries
System requires minimum 105 amp deep cycle marine battery, Series 27 (not
included)
Table 2: Performance chart
Model Discharge height GPH Battery life
SPBB
5’ 1380 9 hours
10’ 900 9 hours
13’ 480 11 hours
SPBB2
5’ 2250 7 hours
10’ 1500 8 hours
13’ 1000 9 hours
3 Product Description