Instructions / Assembly

Table Of Contents
en Original Instructions
28 Installation, Operation and Maintenance Manual
4.4.2 Guidelines for electrical connection
Check that the mains voltage and frequency match the specifications on the data plate.
Protect the supply cord from high temperatures, vibrations, collisions and abrasions.
Check that the power supply line is provided with a short circuit protection device of
appropriate size.
If the pump unit is supplied with a power cord with grounding-type attachment plug, connect
it only to a properly grounded, grounding-type receptacle.
Do not use an extension cord.
If the pump unit is supplied without a power cord, use only a (UL) certified, SJTW type, PVC
insulated and sheathed, hard service flexible cord with copper conductors, with a cross
section of 18 AWG. Follow the next connection steps.
Power cord connection
1. Prepare the power cord:
Strip the wires a
ccording to the next
dimensions in inch (and in mm).
Coat the stripped
copper cores with
lead free solder
or apply end splices of
a proper size.
2.
Unscrew the cable gland components
from the motor housing.
3.
Install the cable gland components
onto the prepared cable.
Take care of the proper order and
orientation.
4. Remove the screw
that holds the end
cap to the motor housing, and remove
the end cap.