Spec Sheet
PAGE 2
Wastewater
Goulds Water Technology
APPLICATIONS
Specially designed for the following uses:
• Basement draining
• Water transfer
• Dewatering
SPECIFICATIONS
• Discharge size: 1
1
⁄2" NPT
• Capacities: to 57 GPM
• Maximum head: 34 feet TDH
• Maximum solids:
3
⁄
8
" spherical
• Temperature: 104º F (40º C) maximum liquid
temperature.
• Maximum pump submergence is 10 ft. for LSP03;
16 ft. for LSP07.
MOTOR
•
Single phase, 3450 RPM, 60 Hz
•LSP03,
1
⁄
3
HP, 115 V, 2.9 maximum amps
• LSP07, ¾ HP, 115 V (7.1 amps) or 230 V (3.5 amps)
• Built-in thermal overload protection with automatic
reset.
• Permanent-split-capacitor type
• Class B insulation
• Stainless steel shaft
•Airlleddesign
• Power cord length: LSP03; 10 feet standard, 20 feet
optional, LSP07; 20 feet.
FLOAT SWITCH OPTIONS
•Modelsareavailablewithaoatswitch.Several
options for automatic operation.
•“AV”modelsaresuppliedwithaverticaloatswitch.
•“A”modelsaresuppliedwithabuiltinoatswitch.
•“AT”modelsaresuppliedwithapiggy-back
replaceableoatswitch.
U
L
®
Underwriters Laboratories
File #83318
CUS
®
Canadian Standards Association
File #LR114251
FEATURES
Corrosion-resistant construction
Stainless Steel motor casing and fasteners
Glass-lledthermoplasticimpellerandcasing.
Upper and lower heavy duty ball bearing
construction.
Motor is permanently lubricated for extended
service life and is powered for continuous
operation.Allratingsarewithintheworkinglimits
of the motor.
Hard coated 400 series stainless steel shaft for
improved corrosion resistance.
Float switch is adjustable for various liquid levels.
Easily removed for direct pump operation or switch
replacement.
Complete unit is lightweight, portable and easy to
service.
Available in manual and automatic versions. See
nextpageforspecicordernumbers.
A double labyrinth lip seal system protects the
motor. It consists of three lip seals and a V-ring in
addition to an impeller counterblade system which
keepssolidparticlesawayfromthesealunit.
AGENCY LISTINGS