INSTALLATION AREA (CONTINUED)
12
VENTILATION - Allow at least 5 inches (13cm) of space at the
DC end of the Pure sine inverter for air flow, 1 inch (2.5cm) on
each side, and 2 inches (5cm) at the AC end of the inverter.
For cooling, the size of the space is not as important as the
overall supply of air. The more clearance for ventilation
around the unit, the better the performance. DO NOT allow
the ventilation openings on the ends of the unit to become
obstructed.
SAFETY - Do not install Pure sine inverter in the same
compartment as batteries or in any compartment capable of
storing flammable liquids like gasoline.
CLOSE THE BATTERY COMPARTMENT AND THE AC
SOURCE AND LOAD PANELS. Avoid excessive cable
lengths (which reduce input and output power due to wire
distance).
CONTINUED ON NEXT PAGE