Data Sheet
Type
:
Rechargeable Nickel Metal
Hydride Cylindrical Cell
Nominal Dimension
(with Sleeve)
:
Φ = 14.5mm
H = 50.5mm
Applications
:
Recommended discharge current
200 to 6000mA
Nominal Voltage
:
1.2V
Capacity
:
Rated:: 2000mAh
Typical: 2100mAh
When discharged at 400mA to
1.0V at 20℃
Charging
Retention
:
80% of nominal capacity after cell
storage at 20℃ for 12 months
When discharged at 400mA to 1.0V
at 20℃
Charging Condition
:
200mA for 16 hrs at 20℃
Fast Charge
:
1000mA to 10000mA (0.5 to 5C)
charge termination control
recommended control parameters:
-△V
:
0-5mV
DT/dt :
0.8℃/min (0.5 to 0.9C)
0.8 - 1℃/min (1C)
TCO :
45 - 55℃
Timer :
105% nominal input
(for ref. only)
Service Life
:
>500 cycles (IEC standard)
not less than 60% of nominal at 0.1C
charge /0.2C discharge
Continuous
Overcharge
:
200mA maximum current for 1 year.
No conspicuous deformation and/or
leakage
Weight
:
27.0g
Internal Resistance
:
Average 12mΩ upon fully charged
(Max. 18mΩ) at 1000Hz
Max. Charging
Voltage
:
1.5V at 200mA charging
Ambient Temperature
Range
:
Standard Charge : 0 to 45℃
Fast Charging : 10 to 45℃
Discharge : -20 to 50℃
Storage : -20 to 35℃
Fast Charge (Charge Control Required )
Model No.: GP210AAHCF
14.5
+0
-1
5.2(ref.)
50.5
+0
-1.3
U nit:m m
Low Rate Discharge
High Rate Discharge
www.gpbatteries.com
The information (subject to change without prior notice) contained in this
document is for reference only and should not be used as a basis for product
guarantee or warranty. Fo
r applications other than those described here, please
consult your nearest GP Sales and Marketing Office or Distributors.
MRS6385 rev.02
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice.
Copyright@GPI International Ltd. – All rights reserved
2000mA
(1C)
100
0
mA
(0.5C)
10A
(5C)