1. Remove the electrical coverplate. (Figure 2) Be
careful not to damage gasket.
2. Route the wiring and conduit to the pump.
3. Attach the ground wire to the pump’s green ground wire.
4. Attach wiring to pump wires.
5. Position all wires inside the pump’s electrical cavity.
6. Replace the electrical coverplate.
Install Hose and Nozzle
NOTE: If installing accessories such as owmeters
or lters, do so now, following the manufacturer’s
instructions.
1. Tighten the hose into the pump outlet.
2. Tighten the nozzle onto the opposite hose end.
3. Place the nozzle into the nozzle holder on the pump
housing. Note that the nozzle cannot be placed in
the holder unless the pump is off.
NOTE: The nozzle holder allows the pump to be locked
when the nozzle is in place.
Before Each Use
Check for leaks around seals or connections. If found,
refer to the Troubleshooting Section. Make sure hoses
are in good condition and connections are tight. Make
sure the work area is dry.
Make sure the tank contains enough fuel.
Check for obvious signs of fuel contamination such as
a loose or missing tank lid which could allow debris into
the tank.
Dispense Fuel
1. To turn the pump on, remove the nozzle from its
holder and push the switch lever up.
NOTE: The nozzle holder and switch are designed so the
pump cannot operate with the nozzle in the holder.
2. Insert the nozzle into the receiving tank or container.
Squeeze the handle to start fuel ow.
This pump is designed to self-prime. If it does not begin
to deliver fuel within 15 to 20 seconds after turning the
pump on and opening the nozzle, turn off and refer to
the Priming and Troubleshooting Sections.
An automatic bypass valve prevents pressure buildup
when the pump is on with the nozzle closed.
4
Figure 2
To avoid personal injury, the pump must be properly
grounded.
WARNING
To prevent physical injury, observe precautions
against re or explosion when dispensing fuel. Do
not operate the system in the presence of any source
of ignition including running or hot engines, lighted
cigarettes, or gas or electric heaters.
WARNING
WARNING
Avoid prolonged skin contact with petroleum fuels.
Use protective goggles, gloves, and aprons in case
of splashing or spills. Change saturated clothing and
wash skin promptly with soap and water.
CAUTION
This pump is designed for use only with gasoline,
kerosene, and diesel fuel. Do not use this pump for
dispensing any uids other than those for which it
was designed. To do so may damage pump compo-
nents and will void the warranty.
CAUTION
Do not leave the system running without uids. “Dry
running” can damage the pump. If the pump fails
to deliver fuel after 15 to 20 seconds, turn OFF and
refer to the Troubleshooting Section.
CAUTION
Do not pump the tank completely dry, as contami-
nants from the tank bottom may enter the pump.
OPERATION
WARNING
Observe precautions against electrical shock when
operating the system. Serious or fatal shock can
result from operating electrical equipment in damp
or wet locations.
WARNING
Inspect external pump wiring regularly to ensure it
is correctly installed and shows no signs of wear.