Maintenance
Daily:
Inspect, clean and replace as needed
D Manifold filter, gun filter and inlet stainer
D Wet cup for leakage, tighten if needed
D TSL level
D Gun trigger safety
D Tip wear, replace if necessary
D Electric cord and plug
Weekly:
D Check tightness of wet cup
D Inspect all high pressure paint hoses
Annually:
D Schedule maintenance check at an autho-
rized Graco repair center
Storage
1. Perform Cleanup, page 31
Tip Wear
12
(305)
11
(280)
9
(229)
5,5
(140)
TIP OPENING ENLARGEMENT
New Tip
.015
Worn to
.017
Worn to
.019
Worn to
.021
FLOW RATE in gpm (lpm) 1/4
(0,87)
1/3
(1,14)
3/8
(1,4)
1/2
(1,74)
Note: A 515 tip produces a 10 in. pattern width when measured 12 in. from tip to work
surface; spraying paint with viscosity of 20 sec #4 Zahn cup and at 1600 psi
(110 bar, 11 M Pa)
NEW
WORN
OUT
SPRAY PATTERN WIDTH
in in ch es (millimeters)
Worn Tips Waste Paint
Cost Mon ey!
2. Wrap cord, place siphon tube set in holder
ti5875b