Instructions-Parts XM™ PFP Hot Water Flush Kit 332073C EN For flushing the XM PFP system with hot water. For professional use only. 100 psi (0.7 MPa, 7 bar) Maximum Inlet Water Pressure to Float Valve 180°F (82°C) Maximum Outlet Fluid Temperature Important Safety Instructions Read all warnings and instructions in this manual and the XM PFP Operation manual. Save all instructions. See Models, page 2 for more information.
Related Manuals Contents Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Component Identification . . . . . . . . . . . . . . . . . . . . 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Connect Air Supply . . . . . . . . . . . . . . . . . . . . . . . . . 6 Connect Water Supply . . . . . . . . . . . . . . . . . . . . . . 6 Priming the Heater . . . . . . . . . . . . . . . .
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
Warnings BURN HAZARD Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns: • Do not touch hot fluid or equipment. EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.
Component Identification Component Identification % * & Key: A B C D ' E F G 3/4 NFR Garden Hose Inlet Heater Pump Hot Water Outlet to Flush Pump Tank Suction Hose (see installation) Air Hose ) ( $ WL E FIG. 1 Hazardous Location XM PFP Non-Hazardous Location XM PFP WL D WL E FIG.
Installation Installation 2. Use four bolts and nuts (4, 5) to install tank (1) onto bracket (2). 3. Follow Connect Air Supply, page 8. Connect air hose (8) to circulation pump (53) and diaphragm pump (P) on the PFP system. The equipment must be grounded to reduce the risk of static sparking and electric shock. Electric or static sparking can cause fumes to ignite or explode. Improper grounding can cause electric shock. Grounding provides an escape wire for the electric current. 4.
Installation Optional Location 2 5. Connect suction hose (F) to the flush pump and insert in the hot water flush tank. See FIG. 1 on page 5 and FIG. 4 on page 7. 6. Connect heater power cable. 1. Use four bolts (4) to connect the three bracket pieces (2, 6, 7). 2. Use four bolts (4 to install the bracket assembly (2) onto system frame. 3. Use four bolts and nuts (4, 5) to install tank (1) onto bracket assembly (2). 4. Follow Connect Air Supply, page 8. a.
Connect Air Supply Connect Air Supply 1. Disconnect air supply (AS) from Heated Fluid Circulation Pump (P) for hose bundle. 2. For Model 24Y132: install the tee (9), nipple (10). The cap (11) is not used. 5. Connect the air hose (8) to the nipple fitting (10). See #2 in FIG. 5. Connect the air hose (8) to the hot water circulation pump (53). AS $6 11 8 P 53 8 WL D $6 8 WL D FIG. 6: Connect Water Supply 1. Connect garden hose to a water supply and the water inlet (A).
Priming the Heater Priming the Heater Equipment surfaces and fluid that is heated can become very hot during operation. To avoid burns and fire and explosions: • Do not touch hot fluid or equipment. • Only use water. NOTICE To prevent damaging the heater element, never turn on the heater without it completely filled with water. 1. Turn on water supply. 2. Loosen needle valve on diaphragm pump to pump water through the heater. 3. Turn the heated water flush switch on the XM PFP sprayer to the ON position.
Parts Parts Hazardous Location Hot Water Flush Kit, 24X113 Non Hazardous Location Hot Water Flush Kit, 24Y132 WL F NOTE: Use sealant on all pipe threads.
Parts Hazardous Hot Water Flush Kit, 24X113 Non Hazardous Hot Water Flush Kit, 24Y132 Hazardous Water Heated Tank, 262937 Non Hazardous Water Heated Tank, 262946 Ref Part 1 262937 262946 2 17B717 3 121488 4 112395 5 112958 6 256254 7 256256 8 248208 9 116504 Ref Part Description Qty 51 17B562 TANK, heated, water 1 52 245863 HEATER (262937 only) 1 245869 HEATER (262946 only) 1 53 24T761 PUMP, Husky 1 54 24W679 CABLE, assembly (262937 only) 1 17G071 CABLE, assembly (262946 only) 55* 24W654 VALVE, body, fl
Technical Data Technical Data PFP Hot Water Flush Kit US Maximum Water Inlet Pressure to Float Valve Maximum Outlet Fluid Temperature Supply Voltage Power Tank Size Inlet Fitting Wetted Parts 12 Metric 7 MPa, 7 bar 82°C 100 psi 180°F 220-250 Volts AC, 1 phase 4000 Watts 10 gallon 37.
Technical Data 332073C 13
Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.