Operation 3A0156A Electric Airless Sprayers ENG - For Portable Airless Spraying of Architectural Coatings and Paints 3300 psi (227 bar, 22.7 MPa) Maximum Working Pressure IMPORTANT SAFETY INSTRUCTIONS Read all warnings and instructions in this manual. Save these instructions.
Models: Models: Model 258719 258720 258722 258872 258873 258874 258876 258877 826124 826125 826127 Model 258723 258724 258878 258879 258881 258882 826128 826129 Model 258727 258728 258883 258884 258886 826130 826131 Model 258763 258764 258765 258766 826132 826133 826134 826135 Model 258729 Model 258730 258887 2 695 ULTRA MAX lIl QuikReel Hi-Boy ✓ ✓ ✓ Lo-Boy ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 795 ULTRA MAX III QuikReel Hi-Boy ✓ ✓ ✓ ✓ ✓ Lo-Boy ✓ ✓ ✓ ✓ ✓ ✓ ✓ 1095 ULTRA MAX III QuikReel Hi-Boy ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable. Grounding Instructions This product must be grounded.
Warnings WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • • • • • • • • • • • • • Do not spray flammable or combustible materials near an open flame or sources of ignition such as cigarettes, motors, and electrical equipment. Paint or solvent flowing through the equipment is able to result in static electricity.
Warnings WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • • • • • • • • • Always wear appropriate gloves, eye protection, and a respirator or mask when painting. Do not operate or spray near children. Keep children away from equipment at all times. Do not overreach or stand on an unstable support. Keep effective footing and balance at all times. Stay alert and watch what you are doing. Do not leave the unit energized or under pressure while unattended.
Component Identification Component Identification 13. 12. 1. 2. 11. 3. 4. 5. 6. 7. 8. 9. 10.
Grounding Grounding The sprayer must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit. The sprayer cord includes a grounding wire with an appropriate grounding contact. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances. Pails Solvent and oil/based fluids: follow local code.
15/20 Amp Switch (Not Available on All Units) 15/20 Amp Switch (Not Available on All Units) 20 ti14919a Select 15A or 20A setting based on your circuit rating. Pressure Relief Procedure 3. Turn pressure to lowest setting. Trigger gun to relieve pressure. 1. Turn power OFF. Wait 7 seconds for power to dissipate. - ti4265a ti14841a 4. Put drain tube in pail. Turn prime valve down to DRAIN position. 2. Lock gun trigger safety. Remove guard and SwitchTip.
Setup Setup 6. Fill throat packing nut with Graco TSL to prevent premature packing wear. Do this each time you spray. 1. Standard Units Only: Connect Graco airless hose to sprayer. Tighten securely. ti13453a 7. Turn power OFF. ti14843a ti4265a 2. Standard Units Only: Connect other end of hose to gun and tighten securely. ti4265a 8. Plug power supply cord into a properly grounded electrical outlet. ti13031a ti2810a 3. Engage gun trigger safety. 9. Turn prime valve down to DRAIN position.
Startup Startup 5. Hold gun against grounded metal flushing pail. Trigger gun and increase fluid pressure 1/2 turn. Flush 1 minute. 1. Turn pressure control to lowest pressure. 1/ 2 ti13243a ti4271a 6. Inspect for leaks. Do not stop leaks with hand or a rag! If leaks occur, perform Pressure Relief Procedure, page 8. Tighten fittings. Perform Startup, steps 1 - 5. If no leaks, proceed to step 7. 2. Turn power ON. ti4266a 7. Place pump in paint pail. ti4266a ti2714a 3.
Switch Tip Installation Switch Tip Installation Spray 1. Spray test pattern. Increase pressure to eliminate heavy edges. Use smaller tip size if pressure adjustment can not eliminate heavy edges. 1. Use spray tip (A) to insert OneSeal™ (B) into guard (C). C B A ti13030a ti13023a 2. Hold gun perpendicular, 10-12 in. (25-30 cm) from surface. Spray back and forth. Overlap by 50%. Trigger gun after moving and release before stopping. 2. Insert Switch Tip. ti13024a ti13025a 3. Screw assembly onto gun.
WatchDog™ Protection System (Not Available on All Units) WatchDog™ Protection System (Not Available on All Units) Pump stops automatically when material pail is empty. Fast Flush To Activate: 1. Perform Startup. To flush the hose and gun at an accelerated speed, perform the following steps: 1. Perform steps 1 - 3 of Cleanup, page 16. 2. Hold gun trigger in and turn prime valve down to DRAIN position and then over to FAST FLUSH. ti7398a 2.
Hose Reel (Not Available on All Units) Hose Reel (Not Available on All Units) 3. Pull reel handle up and turn clockwise to reel in hose. Be sure to keep your head clear of hose reel while winding up hose. 1. Make sure hose is routed through hose guide. ti13502a ti13503a NOTE: The hose reel can be locked into two positions: Usage (A) and Storage (B). (A) (B) ti13504a 2. Lift and turn pivot lock 90° to unlock hose reel. Pull on hose to remove it from hose reel.
Digital Tracking System (Not Available on All Units) Digital Tracking System (Not Available on All Units) Operation Main Menu Job Gallons Short press to move to next display. Press and hold (5 seconds) to change units or reset data. 1. Short press DTS button to move to Job Gallons (or liters x 10). Psi ti13612a ti13620a ti13605a 1. Turn pressure to lowest setting. Trigger gun to relieve pressure. Turn prime valve down to DRAIN position.
Digital Tracking System (Not Available on All Units) Secondary Menu - Stored Data and WatchDog Pump Protection Modes 1. Perform Pressure Relief, steps 1 - 4 if they have not already been done. 7. Short press DTS button. W-DOG scrolls past then OFF displays if watchdog switch is OFF. ON displays if Watchdog switch is ON. 2. Turn power switch on while holding DTS button down. ti4266a ti13608a ti13626a ti13605a 3. SERIAL NUMBER scrolls past and then serial number (e.g. 00001) displays.
Cleanup Cleanup 5. Turn prime valve down to DRAIN position and allow flushing fluid to circulate until flushing fluid appears clear. 1. Perform Pressure Relief Procedure (page 8), steps 1 - 4. Remove siphon tube set from paint and place in flushing fluid. Remove tip guard from gun. ti14842a 6. Turn prime valve forward to SPRAY position. Trigger gun into flushing pail to purge fluid from hose.
Cleanup 9. Remove filters from gun and sprayer, if installed. Clean and inspect. Install filters. ti15018a 10. If flushing with water, flush again with mineral spirits, or Pump Armor, to leave a protective coating to prevent freezing or corrosion. ti2895a Pump Armor 11. Wipe sprayer, hose and gun with a rag soaked in water or mineral spirits.
Technical Data Technical Data Model 695 795 Mark IV 1095 100 - 120V, A, Hz 220 - 240V, A, Hz Generator Minimum W Motor HP (W) 14.8, 50/60 15, 50/60 15, 50/60 15, 50/60 N/A 9, 50/60 10, 50/60 N/A 5000 2.0 (1490) 2.2 (1640) 2.2 (1640) 2.4 (1790) 2.4 (1790) 2.8 (2090) 2.8 (2090) Mark V 1595 Mark V 20/15, 50/60 20/15, 50/60 5000 5000 10, 50/60 10, 50/60 N/A 5000 5000 N/A 5000 5000 Basic Sprayer Wetted Parts..............................
Notes Notes 3A0156A 19
Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.