On/Off Switch Replacement
311911C 23
On/Off Switch Replacement
See Wiring Diagram, page 36.
FinishPro 395
1. Relieve pressure, page 7.
2. Remove four screws (12) and pressure control
cover (50).
Note: Tag wires before removing to ensure wires are
identifiable when assembling.
3. Disconnect three wires (A) from ON/OFF switch (58).
4. Remove toggle boot/nut (30).
5. Remove two yellow wires (B) from ON/OFF switch.
Remove ON/OFF switch.
Installation
1. Connect two yellow wires (B) to ON/OFF switch (58)
2. Install new ON/OFF switch (58). Install toggle
boot/nut (30).
3. Connect three wires (A) to ON/OFF switch.
4. Install pressure control cover (50) with four screws (12).
30
50
12
A
B
58
ti9665a