Operating Guide

Common Procedures
333394R 21
Unclogging Spray Tip
In the event that particles or debris clog the
spray tip, this sprayer is designed with a
reversible spray tip that quickly and easily
clears the particles without disassembling the
sprayer. See for Strain the Paint, page 8 for
additional information.
1. Perform Pressure Relief Procedure,
page 15.
2. To unclog spray tip, turn Prime
Pump/Spray knob down to Prime Pump
position.
3. Reverse spray tip to UNCLOG position.
4. Dual speed models:
Move speed control switch to HIGH
setting.
5. Variable speed models:
Set speed control to 10.
6. Aim sprayer at waste area, turn Prime
Pump/Spray knob forward to spray
position. Pull trigger to clear clog.
NOTICE
Spray tips must be cleaned or stored in
appropriate cleaning fluid (water or mineral
spirits) immediately after use to ensure
material is not allowed to dry in spray tip.
Failure to do so will result in damage to the
spray tip. See Cleanup, page 15.
ti23285a
Prime Pump
ti23290a
SPRAY UNCLOG
ti23359a
10
ti25737a
ti23288a
Spray