Replacement Part List
3A3172C
EN
Kit Instructions
ProXChange
™
 Repair Kit 24Y472
Pressure Relief Procedure
1. Turn ON/OFF switch to OFF position. 
2. Unplug sprayer.
3. Engage trigger lock. Always engage the trigger lock 
when sprayer is stopped to prevent the gun from 
being triggered accidentally.
4. Turn pressure control knob to lowest setting.
5. Put drain tube into a waste pail. Turn prime/spray 
knob down or flip prime/spray lever away from 
sprayer to the PRIME position to relieve pressure.
6. Hold the gun firmly to a pail. Point gun into pail. Dis-
engage the trigger lock and trigger the gun to 
relieve pressure.
7. Engage the trigger lock.
Disassembly
Always perform Pressure Relief Procedure before
starting any pump repairs.
1. On sprayers with a hopper the hopper must be 
removed before pump can be removed. Remove 
airless hose, if necessary remove suction tube.
2. Pull tabs on sides of the easy access door towards 
you.
3. Slide door away from the inlet end of the pump.
4. Now lift the easy access door so that it swivels out 
of the way.
5. Insert hex end of pump into hex tool in the sprayer 
frame and turn counter-clockwise to loosen assem-
bly. Location of the hex varies depending on the 
sprayer.
6. Slide pump assembly off the mounting pins.
7. Remove entire packing assembly from pump hous-
ing including the packing spring.
IMPORTANT SAFETY INSTRUCTIONS
For detailed sprayer information and warnings, see 
the Owners Manual included with your sprayer.
SKIN INJECTION HAZARD: This equipment stays 
pressurized until pressure is manually relieved. To help 
prevent serious injury from pressurized fluid, such as 
skin injection, splashed fluid and moving parts, follow 
the Pressure Relief Procedure whenever sprayer is 
stopped and before sprayer is cleaned or checked, and 
before equipment is serviced.
2
4
ti27463a
3
ti26931a
WARNING