Replacement Part List

Simple repair doubles the pump life.
See instructions inside.
For use with Magnum
®
Pro Sprayers
(except 261815, 261820, 24N906,
24N808) and Graco GX
Sprayers.
Reparación simple duplica la vida de la bomba.
Vea las instrucciones en el interior.
Para el uso con Magnum
®
Pro Pulverizadores
(excepto 261815, 261820, 24N906, 24N808)
y Graco GX
pulverizadores.
graco.com/proxchange
Place
UPC Code
Here
Blue is a trademark of Graco Inc. for Contractor
Equipment Sprayers. Blue es una marca comercial
de Graco Inc. para los Pulverizadores Contractor.
All written and visual data contained in
this document reflects the latest product
information available at the
time of publication.
Graco reserves the right to make
changes at any time without notice.
For patent information,
see www.graco.com/patents.
Original instructions. This manual
contains English. MM 3A3172
Graco Headquarters: Minneapolis,
International Offices: Belgium,
China, Japan, Korea
GRACO INC. AND SUBSIDIARIES
• P.O. BOX 1441 • MINNEAPOLIS
MN 55440-1441 • USA
Copyright 2015, Graco Inc. All
Graco manufacturing locations
are registered to ISO 9001.
www.graco.com
Revision C, May 2018
Assembly
1. On the new pump remove protective cap from the
end of the piston rod.
2. While holding the pump body upside down start
threading the new packing assembly in by hand.
3. Insert hex end of pump into hex tool in the sprayer
frame and tighten. Recommended torque is 300
in.lb (35 N•m).
4. Slide pump assembly onto the mounting pins.
a. Move pump rod up or down until cap is level
with the opening in the yoke.
b. Push on pump rod to slide pump assembly back
on to mounting pins.
5. Swing easy access door closed while pushing the
entire door towards the inlet end of the pump.
6. Install hopper if it was removed and any hoses
removed earlier.
7. Plug sprayer into power source.
NOTE: Door must be fully closed and latched before
sprayer will operate.
When pump packings wear, paint will begin to leak
down outside of pump. Each time the pump kit is
replaced, check pump inlet and outlet valves for wear or
damage. Replace if worn or dam-
aged. Always replace inlet and
outlet valves every second time
the pump kit is replaced.
NOTICE
Be careful not to lose the packing spring that is
installed on the pump rod. Operation without the pack-
ing spring will cause early pump failure.
ti26947a
ti26954a
ti27037a
1
ti27478a
2
3