Start Up
3A4433B 11
1. Install FlexLiner in the cup support.
2. Fill FlexLiner with material. Securely
tighten cup cover onto cup support.
For
proper sprayer operation lid must seal
tightly with the cup.
3. Align VacuValve on cup cover with
Prime Pump/Spray knob. Push cup
assembly onto sprayer and twist to lock.
4. The VacuValve is an important part of
your new sprayer. It is used to evacuate
the air out of the FlexLiner. Open
VacuValve cap.
5.
Tilt the sprayer so the VacuValve is the
highest point, causing any air in the
FlexLiner to rise to the VacuValve.
Gently squeeze the FlexLiner to
evacuate all air through the VacuValve
air hole. Once you see material enter the
VacuValve reservoir, all air should be
evacuated from the FlexLiner.
6. Stop squeezing the FlexLiner and snap
the VacuValve cap closed. You will hear
the cap click when it is closed properly.
ti23361a
ti29719a
ti29720a
ti29721a
ti29722a
ti29723a