Full Product Manual

Cleanup
20 3A4433B
10. Turn Prime Pump/Spray knob forward to
SPRAY position.
11. While holding the sprayer upside down
point the sprayer into a waste pail.
a. With the spray tip in the SPRAY
position, pull the trigger for five
seconds. Release the trigger.
b. Reverse the spray tip to UNCLOG
position, pull the trigger for five
seconds. Release the trigger.
12. If second spray tip was used, remove
cleaned spray tip from spray tip guard
and install second spray tip. See
Spray
Tip Installation
, page 23. Repeat steps
10 and 11 to clean second spray tip.
13. Remove cup assembly and discard used
fluid. Dispose of used cleaning fluid
properly.
14. Replace cleaning fluid and repeat steps
5 – 13 until spray output is clean.
IMPORTANT! For best results, do not spray
more than one cup of water through the tip
while cleaning. If more flushing is needed,
remove the tip from the sprayer to avoid
excessive wear.
15. Remove spray tip, spray tip guard, and
pump filter. Clean with appropriate
cleaning fluid (water or mineral spirits). A
soft brush can be used to loosen and
remove dried material if needed.
ti30231a
ti30232a
ti29768a