Full Product Manual

Cleanup
3A4803B 19
Cleanup
Cleaning your sprayer properly and after every
spray job is of the utmost importance! Proper
care and maintenance will make your paint
sprayer last and work for you trouble free. See
Cleaning Fluid Compatibility
, page 28 and
Static Grounding Instructions (Oil-Based
or flammable materials)
, page 28 for
additional information when using oil-based or
flammable materials.
Cleaning Sprayer
1. Turn Prime Pump/Spray knob to Prime
Pump to relieve pressure.
2. Open the vacuvalve to allow air into the
FlexLiner.
3. Separate the cup support with FlexLiner
from the cup cover/sprayer.
NOTICE
Failure to properly clean sprayer after each
use will result in hardened materials, damage
to the sprayer, and the warranty will no longer
be valid. Do not store solvents other than
mineral spirits in sprayer. Always flush with
Graco Pump Armor prior to storage.
To avoid serious injury or damage to
equipment:
Do not spray solvents through the
spray tip. Clean the tip in a bucket of
compatible solvent.
Clean in a well-ventilated area. Keep a
good supply of fresh air moving through
the area.
When flushing with solvents, always
ground the sprayer and waste
container.
Do not expose the sprayer electronics
to flushing solvents. Keep sprayer at
least 10 in. (25cm) above the rim of the
container when flushing.
ti31167a