Full Product Manual

Storage
3A4803B 23
Storage
With proper storage, the sprayer will be ready
to use the next time it is needed.
Pump Armor fluid protects the sprayer while
in storage. It helps protect sprayer against
freezing and corrosion when not in use.
1. Clean the sprayer and cup assembly.
See Cleanup, page 19.
2. Turn Prime Pump/Spray knob down to
the Prime Pump position. Remove cup
support and FlexLiner. Make certain that
VacuValve cap is closed.
3. Separate the cup support with FlexLiner
from the cup cover/sprayer. Set the
sprayer upside down on a flat surface.
4. Remove pump filter from pump opening.
5. With the sprayer upside-down pour
approximately 2 oz. (60 ml) PUMP
ARMOR into pump opening.
6. Install a clean pump filter into pump
opening.
7. With sprayer upside-down attach cup
support with FlexLiner to sprayer.
8. Holding sprayer upside-down over a
waste container, pull sprayer trigger for
three seconds.
9.
Turn Prime Pump/Spray knob forward to
spray position. Remove cup assembly
and pour any remaining Pump Armour
back into Pump Armor bottle. Replace
child-resistant cap and tighten securely
for storage.
10. Store sprayer indoors in a cool, dry place.
Store in an
upright position only
.
NOTICE
Failure to store sprayer with Pump Armor
can result in operational problems the next
time you spray. Always circulate Pump
Armor through the sprayer after cleaning.
Water or solvents other than mineral
spirits left in the sprayer will corrode
and damage the pump.
ti29755a
ti29770a
ti29771a