Full Product Manual

Reference
28 3A4803B
Cleaning Fluid
Compatibility
Oil-Based or Flammable or
Water-Based Materials
When spraying water-based materials,
flush the system thoroughly with water.
When spraying oil-based or flammable
materials, flush the system thoroughly
with mineral spirits or compatible,
flushing solvent.
To s pray
water-based
materials
after
spraying oil-based
or flammable
materials, flush the system thoroughly
with water first. The water flowing out of
drain tube should be clear and sol-
vent-free
before
you begin spraying the
water-based material.
To spray oil-based or flammable
materials after spraying water-based
materials, flush the system thoroughly
with mineral spirits or a compatible
flushing solvent first. The solvent flow-
ing out of the drain tube should not con-
tain any water. When flushing with
solvents always follow Static Ground-
ing Instructions (Oil-Based or flam-
mable materials), page 28.
To avoid fluid splashing back on your
skin or into your eyes, always aim gun at
inside wall of pail.
Static Grounding
Instructions (Oil-Based or
flammable materials)
Always use a metal pail for oil-based or
flammable materials when sprayer is flushed
or pressure is relieved.
Follow local code. Use only conductive metal
pails, placed on a grounded surface such as
concrete.
Do not place pail on a non-conductive surface
such as paper or cardboard which interrupts
grounding continuity.
The equipment must be grounded to
reduce the risk of static sparking. A static
spark can cause fumes to ignite or explode.
A good ground provides an escape wire for
the electric current.