Precautions for safe handling
Ensure good ventilation of the w ork station. Wear personal protective equipment. Do not breathe
vapours. Keep aw ay from heat, hot surfaces, sparks, open flames and other ignition sources. No
smoking.
Handling temperature
≤ 140 °F
Hygiene measures
Wear personal protective equipment. Take off immediately all contaminated clothing and w ash it
before reuse. Separate w orking clothes from tow n clothes. Launder separately. Do not eat, drink
or smoke w hen using this product. Always wash hands after handling the product.
7.2. Conditions for safe storage, including any incompatibilities
Technical measures
Keep in a cool, w ell-ventilated place away from heat.
Storage conditions
Store in a w ell-ventilated place. Keep container tightly closed. Keep only in original container.
Keep aw ay from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Packaging materials
Store alw ays product in container of same material as original container.
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Graco Pump Armor
USA - ACGIH - Occupational Exposure Limits
ACGIH OEL TWA
5 mg/m³ Contains highly refined petroleum oil
USA - OSHA - Occupational Exposure Limits
OSHA PEL TWA
5 mg/m³ Contains highly refined petroleum oil
OSHA PEL STEL
10 mg/m³ Contains highly refined petroleum oil
ETHYLENE GLYCOL (107-21-1)
USA - ACGIH - Occupational Exposure Limits
Local name
Ethylene glycol
ACGIH OEL TWA
5 mg/m³ Contains highly refined petroleum oil
25 ppm (Vapor fraction)
ACGIH OEL STEL
10 mg/m³ (Inhalable fraction, Aerosol only)
50 ppm (Vapor fraction)
Remark (ACGIH)
TLV® Basis: URT irr. Notations: A4 (Not classifiable as a Human Carcinogen)
Regulatory reference
ACGIH 2023
USA - OSHA - Occupational Exposure Limits
OSHA PEL TWA
5 mg/m³ Contains highly refined petroleum oil
OSHA PEL STEL
10 mg/m³ Contains highly refined petroleum oil
8.2. Appropriate engineering controls
Appropriate engineering controls
Emergency eye w ash fountains and safety showers should be available in the immediate vicinity
of any potential exposure. Ensure good ventilation of the w ork station.
Environmental exposure controls
Avoid release to the environment.
8.3. Individual protection measures/Personal protective equipment
Personal protective equipment:
Wear recommended personal protective equipment.