Precautions for safe handling
:
Ensure good ventilation of the w ork station. Wear personal protective equipment. Do not breathe
vapours. Keep aw ay from heat, hot surfaces, sparks, open flames and other ignition sources. No
smoking.
Handling temperature
:
≤ 140 °F
Hygiene measures
:
Wear personal protective equipment. Take off immediately all contaminated clothing and w ash it
before reuse. Separate w orking clothes from tow n clothes. Launder separately. Do not eat, drink
or smoke w hen using this product. Always wash hands after handling the product.
7.2. Conditions for safe storage, including any incompatibilities
Technical measures
:
Keep in a cool, w ell-ventilated place away from heat.
Storage conditions
:
Store in a w ell-ventilated place. Keep container tightly closed. Keep only in original container.
Keep aw ay from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Packaging materials
:
Store alw ays product in container of same material as original container.
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Graco Pump Armor
USA - ACGIH - Occupational Exposure Limits
ACGIH OEL TWA
5 mg/m³ Contains highly refined petroleum oil
USA - OSHA - Occupational Exposure Limits
OSHA PEL TWA
5 mg/m³ Contains highly refined petroleum oil
OSHA PEL STEL
10 mg/m³ Contains highly refined petroleum oil
ETHYLENE GLYCOL (107-21-1)
USA - ACGIH - Occupational Exposure Limits
Local name
Ethylene glycol
ACGIH OEL TWA
5 mg/m³ Contains highly refined petroleum oil
25 ppm (Vapor fraction)
ACGIH OEL STEL
10 mg/m³ (Inhalable fraction, Aerosol only)
50 ppm (Vapor fraction)
Remark (ACGIH)
TLV® Basis: URT irr. Notations: A4 (Not classifiable as a Human Carcinogen)
Regulatory reference
ACGIH 2023
USA - OSHA - Occupational Exposure Limits
OSHA PEL TWA
5 mg/m³ Contains highly refined petroleum oil
OSHA PEL STEL
10 mg/m³ Contains highly refined petroleum oil
8.2. Appropriate engineering controls
Appropriate engineering controls
:
Emergency eye w ash fountains and safety showers should be available in the immediate vicinity
of any potential exposure. Ensure good ventilation of the w ork station.
Environmental exposure controls
:
Avoid release to the environment.
8.3. Individual protection measures/Personal protective equipment
Personal protective equipment:
Wear recommended personal protective equipment.