Reference
Cleaning Fluid 
Compatibility
Oil- or Water-Based Materials
•
When spraying water-based materi-
als, flush the system thoroughly with 
water.
• When spraying oil-based materials, 
flush the system thoroughly with min-
eral spirits or compatible oil-based 
flushing fluid.
• To spray water-based materials after 
spraying oil-based materials, flush the 
system thoroughly with water first. The 
water flowing out of Drain Tube should 
be clear before you begin spraying the 
water-based material.
• To spray oil-based materials after 
spraying water-based materials, flush 
the system thoroughly with mineral spir-
its or a compatible oil-based flushing 
fluid first. The fluid flowing out of the 
Drain Tube should not contain any 
water. When flushing with oil-based 
flushing fluid always follow Static 
Grounding Instructions (Oil-Based 
Materials), page 29.
• To avoid fluid splashing back on your 
skin or into your eyes, always aim gun 
at inside wall of pail.
Static Grounding 
Instructions (Oil-Based 
Materials)
Always use a metal pail for oil-based 
materials when sprayer is flushed or pressure 
is relieved. 
Follow local code. Use only conductive metal 
pails, placed on a grounded surface such as 
concrete.
Do not place pail on a non-conductive surface 
such as paper or cardboard which interrupts 
grounding continuity.
Always ground a metal pail: connect a 
ground wire to the pail. Clamp one end to the 
pail and the other end to a true earth ground 
such as a water pipe.
To maintain ground continuity when 
sprayer is flushed or pressure is relieved: 
hold metal part of gun firmly to the side of a 
grounded metal pail, then trigger the gun.
The equipment must be grounded to 
reduce the risk of static sparking. Static 
sparking can cause fumes to ignite or 
explode. Grounding provides an escape 
wire for the electric current.
ti24584a