Instructions / Assembly
REVERSIBLE
SPRAY TIPS
STORAGE/PRIMING TOOL
Your sprayer is shipped with a Spray Tip to spray paint. If 
you are spraying stain see the store associate to purchase a 
smaller Spray Tip size.
If your sprayer stops spraying, you most likely have a Spray 
Tip clog. Engage Trigger Lock and reverse the Spray Tip to 
the UNCLOG position. Disengage Trigger Lock and spray into 
a waste area to remove the clog. Engage Trigger Lock and 
return the Spray Tip to SPRAY position. See Owner’s Manual 
for more information.
Use the Storage/Priming Tool if you are 
experiencing difficulty priming your sprayer.
QUESTIONS?
888- 541- 9788
magnum.graco.com/aplus
ti32204a
1
Turn Power Switch OFF. 
Place Suction and Drain 
Tubes in waste pail. Lift 
Prime/Spray Valve to PRIME. 
Turn Pressure Control Knob 
to START position. Trigger 
gun into a waste pail.
2
Engage Trigger Lock. 
Remove Spray Tip Guard 
assembly from gun and 
place in waste pail.
3
Screw Power Flush Valve (included 
with sprayer) to a garden hose. Turn 
on water. Open Power Flush Valve.
Rinse paint off Suction and Drain Tubes, 
inlet screen and Spray Tip and Spray
Tip Guard. Close Power Flush Valve. 
4
Unscrew inlet screen and 
place in waste pail. Thread 
Power Flush Valve to Suction Tube. 
Open Power Flush Valve. Turn 
Power Switch ON and let water run 
through Drain Tube for 20 seconds. 
Turn Power Switch OFF.
5
To save paint in hose, 
disengage Trigger Lock and 
trigger gun into paint pail, lower 
Prime/Spray Valve to SPRAY and 
turn Power Switch ON. When 
water comes out of gun, keep gun 
triggered and aim into waste pail. 
Continue to flush until 
water runs clear.
6
Turn Pressure Control 
Knob to lowest setting 
and release trigger. 
Engage Trigger Lock. 
Lift Prime/Spray Valve to 
PRIME and turn Power 
Switch OFF. 
7
Clean Spray Tip, Spray Tip 
Guard and inlet screen with 
brush. Remove gun filter and 
clean. Reassemble gun filter, 
Spray Tip and Spray Tip guard.
20s
1
Remove Pump 
Armor bottle cap 
and foil seal. If needed, 
unscrew inlet screen 
from Suction Tube.
2 
Lift Prime/Spray Valve 
to PRIME. Place Drain Tube 
in waste pail. Turn Pressure 
Control Knob to START position.
3
While holding the Suction 
Tube above the sprayer, 
pour approximately 2 ounces 
(1/4 cup) of Pump Armor into 
the Suction Tube and turn 
Power Switch ON.
4
When Pump Armor is flushed 
through the sprayer, turn 
Power Switch OFF. Replace 
and tighten child-proof cap 
for storage.
5
Screw inlet screen back 
to Suction Tube. Ensure 
that spray gun and hose 
stay attached to sprayer.
6
Lower Spray/Prime 
valve to SPRAY position 
for storage. Turn Power Switch 
OFF and unplug sprayer from 
outlet. 
3A6454 Revision A, November 2018, Original Instructions. This Quick Guide contains English.
Source Manuals: 3A6430, MM 3A6454. Copyright 2018
CLEANUP
Garden hose cleanup for water-based paints only. 
See Owners Manual for pail cleanup or oil-based materials.
CLEANUP
continued
STORAGE
Perform CLEANUP before STORAGE.
See your Storage/Priming 
Tool Instruction Guide for 
information on how to use 
the Priming/Storage Tool.
SPRAY
UNCLOG
magnum.graco.com/rac
magnum.graco.com/quickcleanup