Replacement Part List
Basic Troubleshooting 
16 312667K
Pressure is set at maximum but 
cannot achieve a good spray pattern.
Spray tip is clogged. Unclog spray tip, see Operation 
manual 312001.
Reversible spray tip is in UNCLOG 
position.
Rotate arrow-shaped handle on 
spray tip so it points forward on gun.
Spray tip is too large for sprayer. Select smaller spray tip.
Spray tip is worn beyond capability of 
sprayer.
Replace spray tip.
Extension cord is too long or not 
heavy enough gauge.
Replace extension cord. See 
Grounding and Electrical 
Requirements, page 10.
Spray gun fluid filter is clogged. Clean or replace spray gun fluid filter, 
see Operation manual 312001.
InstaClean fluid filter is clogged.
(ProX7 and ProX9 Only)
Clean or replace InstaClean fluid 
filter, see Operation manual 312001.
Inlet screen is clogged. Clean debris off inlet screen.
Pump valves are worn. Check for worn pump valves.
a. Prime sprayer with paint
b. Trigger gun momentarily. 
When trigger is released, 
pump should cycle momen-
tarily and stop. If pump con-
tinues to cycle, pump valves 
may be worn.
Material is too thick. Thin material.
Hose is too long (if extra section is 
added).
Remove extra section of hose.
Spray gun stopped spraying. Pump is 
not cycling.
Spray tip is clogged. Unclog spray tip, see Operation man-
ual 312001.
When paint is sprayed, it runs down 
the wall or sags.
Coat is going on too thick. Move gun faster.
Choose a tip with smaller hole size.
Choose tip with wider fan.
Make sure gun is far enough from 
surface.
When paint is sprayed, coverage is 
inadequate.
Coat is going on too thin. Move gun slower.
Choose tip with larger hole size.
Choose tip with narrower fan.
Make sure gun is close enough to 
surface.
Problem Cause Solution