Replacement Part List
Advanced Troubleshooting 
24 312667K
Motor runs and pump cycles, 
but pressure does not build up.
Intake valve or outlet valve is 
not seating properly.
Remove and clean inlet valves and outlet valves. 
Replace if necessary. See List of Kits, page 28.
Pump packings are worn or 
damaged.
Check for leaking around pump. 
ProX7 and ProX9: Replace pump packings. See 
List of Kits, page 28.
X5 and X7: Replace complete pump. See List of 
Kits, page 28.
Specific Problem Cause Solution
General Problem: Excessive Pressure Build Up
Specific Problem Cause Solution
Prime/Spray Valve actuates 
automatically, relieving 
pressure through drain tube.
Pressure control switch has 
pinched wires or switch is 
worn.
Replace pressure control switch using Pressure 
Control Switch Kit, page 28.
Water or paint entered 
pressure control switch or 
shorted control board.
Use Pressure Control Switch Kit, to replace 
switch. See List of Kits, page 28.
Control board failed. See Control Board Diagnostics, page 27. 
Replace damaged control board using Control 
Board Kit, page 28.