User's Manual


Installation
General Information
NOTE:
Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
NOTE:
Always use Genuine Graco Parts and Acces
-
sories, available from your Graco distributor
.
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below
. Also read
the section
FIRE OR EXPLOSION HAZ
-
ARD
on page 4.
1.
Pump:
use a ground wire and clamp as shown in
Fig. 1. Loosen the grounding lug locknut (W) and
washer (X). Insert one end of a 12 ga (1.5 mm
)
minimum ground wire (Y) into the slot in lug (Z)
and tighten the locknut securely
. Connect the other
end of the wire to a true earth ground. Order part
number 222–01
1 Grounding Clamp and Wire.
2.
Fluid and hydraulic hoses:
use only grounded
hoses with a maximum of 500 ft (150 m) combined
hose length to ensure grounding continuity
.
3.
Hydraulic Power Supply:
according to manufactur
-
er
s recommendations.
4.
Spray gun:
ground through connection to a prop
-
erly grounded fluid hose and sprayer
.
5.
Object being sprayed:
follow your local code.
6.
Fluid supply container:
follow your local code.
7.
Solvent pails used when flushing:
follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu
-
ity.
8.
T
o maintain grounding continuity when flushing or
relieving pressure
, hold a metal part of the spray
gun firmly to the side of a grounded
metal
pail,
then trigger the gun.
Fig. 1
Y
W
Z
X
06431