8 307707
Installation
Model 233736
Model 233736 surge tank (A) must be installed
horizontally (see Fig. 4).
Install the surge tank on a short riser tube (B) off the
fluid supply line (D). The air inlet must face up.
Install an air pressure regulator (M) and a ball valve
(N) on the air supply line (P) to the surge tank. The air
regulator controls the air pressure in the tank. The ball
valve prevents air from escaping from the tank during
operation.
Install a fluid valve (T) on the riser tube (B). Close this
valve to allow maintenance of the surge tank while fluid
continues to flow in the main fluid supply line.
Remove the plug (12) and install a fluid priming valve
(R) and drain line (S), for use in bleeding air from the
fluid section.
KEY
A Surge tank
B Riser tube
C Fluid shutoff valve
D Fluid line
E Mix tank
F High-Flo pump
G Ground wire*
H Fluid drain valve*
J Bleed-type master air valve*
M Air regulator
N Air shutoff valve
P Air line to surge tank
R Priming valve
S Fluid drain line
T Fluid valve
U Pump air regulator
* Required for safe operation.
Must be purchased separately.
Fig. 4
Typical Installation
NOTE: This installation is only a
guide for selecting and installing a
system; it is not an actual system
design. Contact your Graco
distributor for assistance in
designing a system to suit your
needs.
B
J*
D
E
A
T
C
J*
F
G*
H*
C
M
N
P
S
R
U
TI1913B
G*