User's Manual
2 307909
Installation
Pressure Relief Procedure
WARNING
INJECTION HAZARD
The system pressure must be manually
relieved to prevent the system from
starting or spraying accidentally. Fluid
under high pressure can be injected through the
skin and cause serious injury. To reduce the risk of
an injury from injection, splashing fluid, or moving
parts, follow the Pressure Relief Procedure
whenever you:
D are instructed to relieve the pressure,
D stop spraying,
D check or service any of the system equipment,
D or install or clean the spray tips.
1. Engage the spray gun or dispensing valve safety
latch.*
2. Disengage the gun or dispensing valve safety
latch.*
3. Hold a metal part of the gun or valve firmly to a
grounded metal waste container and trigger it to
relieve the fluid pressure.*
4. Engage the safety latch again.*
5. Open the pump drain valve (required in system),
having a container ready to catch the drainage.
6. Leave the drain valve open until you are ready to
spray again.
*Applies only when using a spray gun or
dispensing valve.
7. If you suspect that the spray tip, nozzle, or hose
is completely clogged or that pressure has not
been fully relieved after following the steps above,
very slowly loosen the hose end coupling and
relieve pressure gradually, then loosen completely.
Now clear the tip, nozzle, or hose obstruction.